When the surface of the clear ground space is constructed of concrete, asphalt, or boards, the slope of the clear ground space must be no steeper than 1:48 (2 percent) in any direction....
Search Results "Floor Slope"
Commonly Searched Documents
-
Surface, Slope, and Openings [1011.2.2, 1011.2.3, and 1011.2.4]
-
Size: ADA Standard Section 305.3
Section 305.3 covers the current ADA Standards for the required size of compliant clear floor or ground space.
-
General: ADA Standard Section 305.1
Section 305.1 of the ADA Standards covers information in the current ADA Standards for clear floor or ground space.
-
Clear Floor or Ground Space: ADA Standard Section 707.2
A clear floor or ground space complying with 305 shall be provided....
- Figure 406.2 Counter Slope of Surface Adjacent to Curb Ramps – Drawing from the U.S. Access Board
-
Approach: ADA Standard Section 305.6
Section 305.6 covers the current ADA Standards for the approach to clear floor space.
-
1.1.4
1.1.4 A maximum overall design running slope for exterior accessible ramps of 7.5% (1:13.3 or 1:13) is recommended....
-
5.1.2 Level or Sloped Entry
Camp shelters providing roll-in access shall have a level or sloped entry that complies with the FSORAG Outdoor Recreation Access Route technical provisions if the camp shelter is in a campground...
-
Ground Floor
This floor will be considered to be a ground floor. Specific comments concerning ground floor units are as follows: Comment....
-
Cross Slope [1016.7.2]
Cross slope is the side-to-side slope of the surface of an ORAR....
-
1.1.6 Flatness of walk cross slope
1.1.6 Flatness of walk cross slope....
-
4.1.6(4)(a)
Curb ramps and ramps to be constructed on existing sites or in existing buildings or facilities may have slopes and rises as shown in Table 2 if space limitations prohibit the use of a 1...
-
4.1.6(3)(a)(ii)
(ii) A slope between 1:8 and 1:10 is allowed for a maximum rise of 3 inches. A slope steeper than 1:8 is not allowed....
-
11B-704.2.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided. The clear floor or ground space shall not be obstructed by bases, enclosures, or seats....
-
4.1.6(3)(a) Ramps
(a) Ramps: Curb ramps and interior or exterior ramps to be constructed on sites or in existing buildings or facilities where space limitations prohibit the use of a 1:12 slope or less may...
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48....
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48....
-
Overlap: ADA Standard Section 603.2.2
Section 603.2.2 covers the current ADA Standards for overlapping clear floor space at fixtures and turning spaces in toilet and bathing rooms.
-
Changes in Level [4.5.2]
Changes in level ¼ to ½ inch must be beveled with a slope no greater than 1:2....
-
A4.8.1 General
Ramps are essential for wheelchair users if elevators or lifts are not available to connect different levels. However, some people who use walking aids have difficulty with ramps and...
-
A4.8.1 GENERAL
Ramps are essential for wheelchair users if elevators or lifts are not available to connect different levels. However, some people who use walking aids have difficulty with ramps and...
-
Door Swing: ADA Standard Section 603.2.3
Section 603.2.3 covers the current ADA Standards for door swings at clear floor space and clearances at fixtures in toilet and bathing rooms.
-
Step 3: Apply the Accessibility Provisions
This step involves looking at FSTAG, sections 7.4.1 through 7.4.8, which contain the technical requirements for trail grade, cross slope, resting interval, surface, clear tread width, passing...
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....