[ADA Stds 4.13.6, figure 25] Note: The maximum threshold height is 1/2 inch for new construction....
Search Results "Figures"
Commonly Searched Documents
-
D4. Door Clearance
-
1132A.4, Item 4
(See Figure 11A-8K)....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
See Figures 11B-604.8.1.1.2 (b) and 11B-604.8.1.1.3 (b)....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
See Figure 11B-604.8.1.1.2....
-
11B-809.10.6.1 Size
to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the shower wall as illustrated in Figure...
- ADA Helper App
-
11B-610.3.1 Rectangular seats
FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT...
-
11B-802.2.1.2 Lines of sight between heads
FIGURE 11B-802.2.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS...
-
608.3.3 Alternate Roll-In Type Shower Compartments
Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers...
-
11B-307.3.1 Edges and corners
FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS...
-
610.3.1 Rectangular Seats
Figure 610.3.1 Rectangular Shower Seat...
-
505.10.3 Bottom Extension at Stairs
Figure 505.10.3 Bottom Handrail Extension at Stairs...
-
802.2.1.1 Lines of Sight over Heads
Figure 802.2.1.1 Lines of Sight over the Heads of Seated Spectators...
-
802.2.2.1 Lines of Sight over Heads
[ECTCR UFAS 4.33.3] Figure 802.2.2.1 Lines of Sight over the Heads of Standing Spectators...
-
505.10.1 Top and Bottom Extension at Ramps
[ECTCR UFAS 4.8.5(6), Fig. 17] Figure 505.10.1 Top and Bottom Handrail Extension at Ramps...
-
Location of overhead signage (slide 15)
Overhead signage is great for navigating wayfinding; make sure [that it] also [is] at a large scale [and] at a lower level that people can get close to it and really figure out what that...
-
e-ii
[ADA Standards § 4.10.9, Fig. 22] Yes No Note: See Figure 22 for acceptable floor and opening dimensions....
-
802.1.3 Depth
Figure 802.1.3 Depth of Wheelchair Spaces in Assembly Areas...
-
505.10.1 Top and Bottom Extension at Ramps
Figure 505.10.1 Top and Bottom Handrail Extension at Ramps...
-
§ 36.406(b) Scope of coverage.
Unless specifically stated otherwise, the advisory notes, appendix notes, and figures contained in the 1991 Standards and 2010 Standards explain or illustrate the requirements of the rule...
-
505.10.2 Top Extension at Stairs
Figure 505.10.2 Top Handrail Extension at Stairs...
-
407.12.1.1 Vertical Plane for Side Reach (Section-by-Section Analysis)
This side reach requirement mirrors existing 508 Standards § 1194.25(j)(1) and Figure 1....
-
4.1.6(3)(c)(iii)
For example, an elevator of 47 in by 69 in (1195 mm by 1755 mm) with a door opening on the narrow dimension, could accommodate the standard wheelchair clearances shown in Figure 4....