Section 100.205(c)(3)(iv) requires that covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all...
Search Results "Adaptive Sports"
-
Requirement 7. Usable kitchens and bathrooms.
-
Requirement 7 -- Usable Kitchens and Bathrooms
[See subsections ...]
-
26.1 Q. Is a parallel approach required at the shower, as shown in Figure 7(d) of the Guidelines?
A. Yes. For a 36 x 36 shower, as shown in Figure 7(d), a person in a wheelchair would typically add a wall hung seat. Thus the parallel approach as shown in Figure 7(d) is essential...
-
§100.205(c)(3)(iv)
(iv) Usable kitchens and bathrooms such that an individual in a wheelchair can maneuver about the space.
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
SECTION 1128A COVERED DWELLING UNITS
[See subsections ...]
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
§100.205(c)(3)
(3) All premises within covered multifamily dwelling units contain the following features of adaptable design:...
-
7(2)(a)(ii)
Fig. 7 Clear Floor Space for Adaptable Bathrooms...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
building with one common (lobby) entrance, located on a site with difficult terrain conditions or unusual characteristics: All ground floor units in non-elevator buildings shall be adaptable...
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
A. Yes, as long as the necessary clear floor space shown in Figure 7(a) is provided. This would mean that the wing wall could not extend beyond the front edge of a lavatory located...
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
11B-233.3.4.1 Alterations to vacated buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling...
-
11B-233.3.1.2.6.3 Test number two, site analysis test
For a site having multiple buildings, or a site with a single building with multiple entrances, it is not required to provide a building entrance on an accessible route to all ground...
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower...
-
§100.205(c)(3)(iii)
(iii) Reinforcements in bathroom walls to allow later installation of grab bars around the toilet, tub, shower, stall and shower seat, where such facilities are provided; and
-
11B-233.3.5 Dispersion
Residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and residential dwelling units required to provide communication...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length...
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4. Exception: Removable base cabinets...
-
11B-233.3.1.2.5 Public housing facility site impracticality
The number of adaptable residential dwelling units required in non-elevator building public housing facilities shall be determined in accordance with Chapter 11A, Section 1150A.1....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.