Stainless steel faceplate is scratch/scuff resistant and will not deteriorate or rust from exposure to liquids and other cleaning products Graphics are etched onto the faceplates for maximum...
Search Results "Maximum Extent Practicable"
- BEA Inc. PBDGP Series Vestibule Push Plate (Push to Open)
- American Standard Colony PRO Laundry Faucet 7074.140
- Hager Companies 5100 Series - Heavy Duty Surface Door Closer
-
FPX Assessments: Advancing Evaluation Through Real-World Competence
Moving Beyond Conventional Assessment Standardized tests measure knowledge but rarely evaluate practical skills or decision-making under pressure....
-
§ 382.45 Passenger information
Carrier personnel shall not require any qualified individual with a disability to demonstrate that he or she has listened to, read, or understood the information presented, except to the extent...
-
11B-202 Existing buildings and facilities
When the cost of full compliance with Section 11B-202.4 would exceed 20 percent, compliance shall be provided to the greatest extent possible without exceeding 20 percent....
-
11B-101.1 General
The requirements are to be applied during the design, construction, additions to, and alteration of sites, facilities, buildings, and elements to the extent required by Chapter 1, Section...
-
III-4.4600 Seating in assembly areas
And in order to facilitate seating of wheelchair users who wish to transfer to existing seating when fixed seating is provided, a public accommodation must provide, to the extent readily...
-
III-5.3000 Application of ADAAG
In such cases, the ADAAG standards should be applied to the extent possible. Where appropriate technical standards exist, they should be applied....
-
20. DESIGN AND CONSTRUCTION STANDARDS
(b) For the term of the Consent Decree, to the extent that HWI creates new prototype building plans or designs for accessible rooms or other elements required to be accessible ( e.g., signage...
-
11B-101.1 General
The requirements are to be applied during the design, construction, additions to, and alteration of sites, facilities, buildings, and elements to the extent required by Chapter 1, Section...
-
11B-101.1 General
The requirements are to be applied during the design, construction, additions to, and alteration of sites, facilities, buildings, and elements to the extent required by Chapter 1, Section...
-
Expert Report of James L.E. Terry, Evan Terry Associates, LLC (August 9, 2018)
Center, 12303 Sonnier Street, Houston, TX Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum...
-
1008.4.3 Play Tables
The tops of rims, curbs, or other obstructions shall be 31 inches (785 mm) high maximum....
-
M302.4.1 Clearance in Base
Equipment components are permitted to be located within 8 inches (205 mm) maximum of the centerline of the clearance width....
-
M301.4.1 Clearance in Base
Components of diagnostic equipment are permitted to be located within 8 inches (205 mm) maximum of the centerline of the clearance width....
-
1607.8.2 Grab bars, shower seats and dressing room bench seats
room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar or seat so as to produce the maximum...
-
703.4.1 Height Above Finish Floor or Ground
characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum...
-
407.2.1.4 Location
Responding cars are programmed for maximum efficiency by reducing the number of stops any passenger experiences....
-
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment The Committee recommends a maximum distance of 1 1/2 inches from the transfer surface to the...
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
R304.2.3 Flared Sides
Where a pedestrian circulation path crosses the curb ramp, flared sides shall be sloped 10 percent maximum, measured parallel to the curb line. Advisory R304.2.3 Flared Sides....
-
7.2(1)
are provided for sales or distribution of goods or services to the public, at least one of each type shall have a portion of the counter which is at least 36 in (915mm) in length with a maximum...
-
Parking Meters and Parking Pay Stations (R309.5) (Section-by-Section Analysis)
Displays and information must be visible from a point located 1 meter (3.3 feet) maximum above the center of the clear space in front of the parking meter or parking pay station....