length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section 11B-405.2 _|Slope...
Search Results "Sloped Area"
-
11B-1003.2.2 Boarding piers at boat launch ramps
-
307.3 Post-Mounted Objects
EXCEPTION: The sloping portions of handrails serving stairs and ramps shall not be required to comply with 307.3. Figure 307.3 Post-Mounted Protruding Objects...
-
Q8: Curb Ramp Replaced as Part of a Resurfacing Alteration and Adjacent Sidewalk
Public entities are required to address other barriers on existing sidewalks, such as steep cross slopes or obstructions, as part of their on-going program access and transition plan obligations...
-
Seats
The deck surface between the centerline of the seat and the pool edge cannot have a slope greater than 1:48....
-
Landings [4.8.4]
Landings must be at least as wide as the ramp they serve and cannot slope more than 2% in any direction. Where ramps change direction, the landing must be at least 60 by 60 inches....
-
Diagonal Curb Ramps [§406.6]
The orientation also can mislead people with vision impairments who use curb slopes as a cue to crossings....
-
Stairs
At the bottom, the handrail shall continue to slope for a distance of the width of one tread from the bottom riser; the remainder of the extension shall be horizontal (see Fig. 19(c) and...
-
11B-1003.2.2 Boarding piers at boat launch ramps
length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section 11B-405.2 _|Slope...
-
Wheelchair seating locations must be on an accessible route
• Wheelchair seating locations must be on an accessible route that provides access from parking and transportation areas and that connects to all public areas, including concessions, restaurants...
-
M6
Inside the room is there an area for a person who uses a wheelchair to turn around - either a 60-inch diameter circle or a “T”-shaped turn area?...
-
907.2.6.2.2 Manual fire alarm boxes
Manual fire alarm boxes are not required to be located in accordance with Section 907.3 where the fire alarm boxes are provided at staff-attended locations having direct supervision over areas...
-
10.4.1(4)
public pay telephones are located in any of the following locations, at least one public text telephone shall also be provided in that location: (a) a main terminal outside the security areas...
-
1132A.4 Level floor or landing
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
Clear Floor Space: Minimum Clear Floor Space Required - Manual, Power & Scooter
Clear floor area dimensions are used for determining the size of spaces designated for wheeled mobility users (such as on buses, in movie theaters, sports stadiums)....
-
11B-206.3 Location
Accessible routes shall coincide with or be located in the same area as general circulation paths....
-
11B-206.3 Location
Accessible routes shall coincide with or be located in the same area as general circulation paths....
-
11B-206.3 Location
Accessible routes shall coincide with or be located in the same area as general circulation paths....
-
Altered Rides
An existing ride is also considered an altered ride if the load or unload area is newly designed or constructed....
-
206 Accessible Routes
In addition, there are provisions specific to restaurants and cafeteria dining areas, performance areas, press boxes, employee work areas, and various types of recreation facilities....
-
PATH OF TRAVEL
area with an exterior approach (including sidewalks, streets, and parking areas), an entrance to the facility, and other parts of the facility....
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
F217.4.8 Detention and Correctional Facilities
In detention and correctional facilities, where at least one pay telephone is provided in a secured area used only by detainees or inmates and security personnel, at least one TTY shall...
-
11B-217.4.8 Detention and correctional facilities
In detention and correctional facilities, where at least one pay telephone is provided in a secured area used only by detainees or inmates and security personnel, at least one TTY shall...