The surface of the bottom tread shall extend to a water depth of 18 inches (455 mm) minimum below the stationary water level. Advisory 1009.5.4 Transfer Steps....
Search Results "Ramp Surface"
Commonly Searched Documents
-
Transfer Steps: ADA Standard Section 1009.5.4
-
Height: ADA Standard Section 1005.2.1
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
Clear Width: ADA Standard Section 403.5.1
Section 403.5.1 covers the current ADA Standards for the clear width of walking surfaces that are part of an accessible route.
-
Circulation Path
An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, hallways, courtyards, elevators, platform lifts, ramps, stairways, and landings...
-
E1-3. Route Level Changes
Does the route from the accessible entrance to the voting area change levels using a ramp, lift or elevator? Yes _____ No _____ If no, go to question E1-7....
-
E1-4. Accessible Route Slope
Where the slope of the accessible route is greater than 1:20, does this part of the accessible route meet the following requirements for an accessible ramp? Yes _____ No _____...
-
11B-246.5 Picnic areas
Where picnic tables are provided, at least one picnic table, and one additional table for each 20 tables or fraction thereof, shall be accessible and comply with Section 11B-902 _|Dining Surfaces...
-
11B-246.5 Picnic areas
Where picnic tables are provided, at least one picnic table, and one additional table for each 20 tables or fraction thereof, shall be accessible and comply with Section 11B-902 _|Dining Surfaces...
-
PRIORITIES
These measures include, for example, installing an entrance ramp, widening entrances, and providing accessible parking spaces....
-
Changes in Level within a Dwelling Unit
To require a ramp or other means of access to such an area, at the time of construction, would reduce, perhaps significantly, the space provided by the area....
-
904.4.1 Parallel Approach
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
1133A.3 Removable base cabinets
Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with a knee and toe space complying with Section 1133A.7....
-
§ 38.97(a)
The diameter or width of the gripping surface of interior handrails and stanchions shall be 11/4 inches to 11/2 inches or shall provide an equivalent gripping surface....
-
Test Procedures
Accessibility and Durability Measures The beach path surfaces were periodically measured with a rotational penetrometer....
-
Klingstone 400
) and a very small amount of loose fines coming to the surface....
-
§382.97(c)
(c) Any other aircraft model determined by the Department of Transportation to be unsuitable for boarding and deplaning assistance by lift, ramp, or other suitable device....
-
§27.75(a)(3)(ii)
(ii) It would be infeasible for mobility-limited persons to reach the over-passes, under-passes or ramps because of unusual topographical or architectural obstacles unrelated to the federally...
-
21.1 Q. Is a dwelling unit that has a split entry foyer...required to be accessible if it is a ground floor unit in a covered multifamily dwelling?
This would preclude a split level foyer, unless a properly sloped ramp can be provided....
- SciFit Inclusive Fitness PRO1 - Upper Body Machine
-
Background
the contaminant or force is removed, the surface returns to its original condition.”...
-
STORY
That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
-
Why test on straight courses and P-shaped turning courses?
However, the cost for producing these course designs with a number of surface materials would be very large....
-
STORY
[DSA-AC] That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524...