Although ramps with a slope slightly less than 1:12 take up more floor space, the negligible loss in usable space will more than compensate for potential problems caused by rebuilding or...
Search Results "Ceramic Tile Flooring"
Commonly Searched Documents
- 
    
  
  1.1.1
  
 - 
    
  
  11B-703.7.2.6 Toilet and bathing facilities geometric symbols
  
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...
 - 
    
  
  11B-1008.2.3 Water play components
  
Exceptions: Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302,...
 - 
    
  
  1009.7.2 Separation
  
The fire-resistance-rated construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever...
 - 
    
  
  Guest Rooms
  
At least on sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
 - Inclinator VL Vertical Platform Lift
 - Sunlighten Community Solocarbon® Far Infrared Sauna
 - Aurora Doors Sliding Barn Door
 - CRL-Blumcraft® Panic Handles 08 7100
 - 
    
  
  Table of Contents
  
Play Areas 241 Saunas and Steam Rooms 242 Swimming Pools, Wading Pools, and Spas 243 Shooting Facilities with Firing Positions CHAPTER 3: BUILDING BLOCKS 301 General 302 Floor...
 - Panda S.15 All Wood with Aluminum Core Lift & Slide System
 - Panda S.12 Solid Wood Lift & Slide System
 - 
    
  
  Character Height: ADA Standard Section 703.5.5
  
Table 703.5.5 Visual Character Height Height to Finish Floor or Ground From Baseline of Character Horizontal Viewing Distance Minimum Character Height 40 Inches...
 - 
    
  
  Toilet Rooms and Bathing Rooms: ADA Standard Section 213.2
  
Section 213.2 covers scoping requirements in the current ADA Standards for toilet rooms and bathing rooms.
 - 
    
  
  Construction and Manufacturing Tolerances: ADA Standard Section 104.1.1
  
Section 104.1.1 of the ADA Standards covers the most current information on dimensions in regards to construction and manufacturing tolerances in the ADA Standards.
 - 
    
  
  11B-206.2.4 Spaces and elements
  
benches, clerks' stations, bailiffs' stations, deputy clerks' stations, and court reporters' stations shall not be required to provide vertical access provided that the required clear floor...
 - Acoustiguide Custom Multimedia Content Application
 - Panda IS.14 All Aluminum IMPACT Lift & Slide System
 - Panda S.65 All Aluminum with Aluminum/Wood Clad Multi-Slide Door System
 - 
    
  
  M301.3.1 Transfer Supports
  
Figure 5.3-10: Illustration of a concept (not to scale) for a detachable floor mounted support....
 - 
    
  
  B. The ADA Standards for Accessible Design
  
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
 - 
    
  
  D. Reasonable Modifications
  
However, some people have disability-related needs for cots to be modified or may need to sleep on cots or beds instead of on mats placed on the floor....
 - 
    
  
  205 Operable Parts
  
by service or maintenance personnel (Exception 1) electrical or communication receptacles serving a dedicated use (Exception 2) certain outlets at kitchen counters (Exception 3) floor...
 - 
    
  
  Summary of Major Provisions
  
The final rule adds new technical requirements for floor surfaces, bedrooms, and weather alert systems in emergency transportable housing units with mobility features....