Exception: Existing buildings shall be permitted to have a visible identification fixture with a car designation character adjacent to each elevator car entrance centered at 72 inches (1829...
Search Results "Building Use"
Commonly Searched Documents
-
11B-411.2.2.1 Visible identification
-
907.5.2.3.2 Groups R-1 and R-2.1
Visible alarms shall be activated by the in-room smoke alarm and the building fire alarm system....
-
ACCESSIBLE DWELLING UNITS
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
- Besam SW200i Surface Mounted Swing Door Operator
- DORMA 9000 Series Exit Device
- Norton 6000 Series Low Energy Operator
-
ETA Opinion: ADA Signage at Exit Doors
Similar language appears in the year 2000 International Building Code scoping in §1109.3 Other Signs....
-
Avoid the extremes of surface reflectivity and contrast (slides 11 and 13)
Flooring [As shown in slide 11 photo, this room is] fairly successful; [it] could use some tweaking when you look at it from that point of view....
-
X. Alterations
Elevators are not required in facilities under three stories or with fewer than 3,000 square feet per floor, unless the building is a shopping center, shopping mall, professional office...
-
Other international standards
Australian NATSPEC Reference Volume 1: Building Works, Concrete Finishes Section Three classes of surface finish based on using a straightedge method of testing: Class A...
-
"Existing Facility" (Section-by-Section Analysis)
In contrast, the term "existing facility" is not defined although it is used in the statute and in the regulations for titles II and III. 42 U.S.C. 12182(b)(2)(A)(iv); 28 CFR 35.150....
-
New Construction
This chapter contains important introductory and interpretive information, including definitions for key terms used in the 2010 Standards. Chapter 2: Scoping....
-
Will you need assistance in an emergency evacuation?
Do you experience any of the following conditions that could interfere with your ability to quickly evacuate a building?...
-
1136A.1 Receptacle heights
Baseboard electrical outlets used in relocatable partitions, window walls or other electrical convenience floor outlets are not subject to the minimum height requirements....
-
11B-215.1 General
Facility alarm systems (other than fire alarm systems) such as those used for tornado warnings and other emergencies are not required to comply with the technical criteria for alarms in...
- Adaptive Access
-
1117B.2.8
SECTION 1117B - OTHER BUILDING COMPONENTS 1117B.2 Telephones. 1117B.2.8 Telephone equipment for hearing impaired persons. ...
-
233.3.4 Additions, F233.3.3 Additions, F233.4.4 Additions
Where an addition to an existing building results in an increase in the number of residential dwelling units, the requirements of 233.3.1.1 and 233.3.2.1 shall apply only to the residential...
-
Deferred Maintenance
Maintenance work includes improving accessibility as well as compliance with building codes....
-
Alterations [4.1.6(1)(f) & (k)]
Thus, the exception from the requirement for an elevator in buildings with less than 3 stories or with less than 3,000 square feet per floor applies to altered facilities as well, including...
- Eye to Eye
-
III-1.2000 Public accommodations
ILLUSTRATION: A medical care provider owns one building in which patients are seen, and another building in a different location that contains only administrative offices....
-
206.7 Platform Lifts
Platform lifts shall be permitted as a component of an accessible route in an existing building or facility....
-
Story
That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....