The first test is an individual building test which involves a two-step process: measurement of the slope of the undisturbed site between the planned entrance and all vehicular or pedestrian...
Search Results "Pedestrian Facility"
Commonly Searched Documents
-
(1) Site impracticality
-
Storage: ADA Standard Section 804.5
At least 50 percent of shelf space in storage facilities shall comply with 811....
-
VEHICULAR WAY
[DSA-AC] A route provided for vehicular traffic, such as in a street, driveway, or parking facility....
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
A. DEFINITIONS AND BACKGROUND
buildings or facilities in such a manner that those buildings or facilities meet the requirements of title III of the ADA, including the Standards. 3....
- Corbin Russwin Inc. FE6800 Fortified Multi-Point Latching System
- Yale 4400 Series Institutional Door Closer
-
Assessment factors. (Section-by-Section Analysis)
individuals with mobility disabilities; the places, times, or circumstances under which the use of the other power-driven mobility device is or will be restricted or prohibited; safety, pedestrian...
-
Detectable Warnings [4.29]
Where curbs are lacking, such as at curb ramps, vehicle drop-offs, and depressed corners at intersections, people with vision impairments may not be able to discern the boundary between pedestrian...
-
R402.3 Post-Mounted Objects
Where objects are mounted on free-standing posts or pylons and the objects are 685 mm (2.25 ft) minimum and 2030 mm (6.7 ft) maximum above the finish surface, the objects shall overhang pedestrian...
-
Selection of Participants
Selection of Participants The principal investigators at OSU were to pilot test the survey instruments with professional contacts in parks and recreation that manage pedestrian trails...
-
4.7.10 DIAGONAL CURB RAMPS
If diagonal (or corner type) curb ramps have returned curbs or other well-defined edges, such edges shall be parallel to the direction of pedestrian flow....
-
§100.205(e)(2)(v) 2003 International Building Code (IBC)
the 2003 IBC stating, “ICC interprets Section 1104.1, and specifically, the Exception to Section 1104.1, to be read together with Section 1107.4, and that the Code requires an accessible pedestrian...
-
1.1.8 Alternate measurement tools
If the F - number system is used pedestrian paths should have a minimum FF of 25. Running slope should be measured along the same lines of measurements as given in Section 1.1.3....
-
1.1.7 Measurement of parking areas
These areas should be considered as a pedestrian walk with a minimum width of 60 in. and a length of approximately 20 ft and with an ADA/ABA - AG maximum slope of 1:48 in both directions...
-
Administrative Authority
A governmental agency that adopts or enforces regulations and guidelines for the design, construction, or alteration of buildings and facilities....
-
Service Entrances: ADA Standard Section 206.4.8
Section 206.4.8 covers scoping requirements in the most current ADA Standards for accessible routes to service entrances.
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
-
Spaces and Elements: ADA Standard Section 206.2.4
Section 206.2.4 covers the scoping requirements in the most current ADA Standards for accessible routes connecting spaces and elements within a building.
- Hager Companies 3700 Series Interconnected Lock
- Mitsubishi Jet Towel Mini Hand Dryer
- Mitsubishi Jet Towel Slim Hand Dryer
-
Site Impracticality Determinations
arrival points; and measurement of the slope of the planned finished grade between the entrance and all vehicular or pedestrian arrival points....
-
General: ADA Standard Section 216.1
Section 216.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for signs.