A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided....
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
11B-904.4.2 Forward approach
-
903.4 Back Support
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Grab Bars
If a grab bar is provided on each step, the top of the gripping surface must be 4 inches minimum to 6 inches maximum above each step....
-
Safe Harbor – Construction Prior to March 15, 2012
For example, the 1991 Standards allow 54 inches maximum for a side reach range to a control such as the operating part of a paper towel dispenser....
-
903.4 Back Support
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
4.5.3* CARPET
The maximum pile height shall be 1/2 in (13 mm). Exposed edges of carpet shall be fastened to floor surfaces and have trim along the entire length of the exposed edge....
-
Carpet [§302.2]
The standards specify the maximum pile height (1/2” measured to the backing, cushion, or pad) and texture (level or textured loop, level cut pile, or level cut/uncut pile) and require firm...
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided....
-
11B-604.7 Dispensers and disposal units
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
11B-411.2.1.2.3 Accessibility function button
Each dot shall have a base diameter of 0.059 inch (1.5 mm) minimum and 0.063 inch (1.6 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
Re: 206.2.5 Restaurants and Cafeterias
This code applies to fixed or built-in elements of buildings, structures, site improvements and pedestrian routes or vehicular ways located on a site....
-
Resources
Resources The Department of Justice offers technical assistance on the ADA as it applies to businesses, non-profit service agencies, and State and local government programs....
-
A.5 - Are there regulations implementing Section 508?
The Access Board’s standards consist of several subparts which, among other things: define EIT (see 36 CFR 1194.4); set forth "technical provisions" that: address...
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
F224.1 General
The Fair Housing Amendments Act requires that certain residential structures having four or more multi-family dwelling units, regardless of whether they are privately owned or federally...
-
704.10 Vertical exposure
For buildings on the same lot, approved protectives shall be provided in every opening that is less than 15 feet (4572 mm) vertically above the roof of an adjoining building or adjacent structure...
-
709.4 Continuity
to outside wall and from floor slab to floor or roof deck above, including continuity through concealed spaces, such as those found above suspended ceilings, and including interstitial structural...
-
4.21.3 Seat
The structural strength of seats and their attachments shall comply with 4.26.3....
-
§ 37.47(e)
Extensions may be granted only with respect to key stations which need extraordinarily expensive structural changes to, or replacement of, existing facilities (e.g., installations of elevators...
-