The bottom log should be removed from the gate shown in figure 6 because the log could be a tripping hazard and it prevents wheelchair access....
Search Results "On-Board Wheelchair"
-
Horse Accessible Gates
-
Technical Requirements for Accessible Hiker/Pedestrian Trails
Wheelchair dimensions, clear space, maneuvering room, and reach ranges found in Architectural Barriers Act Accessibility Standards (ABAAS) are the basis for trail designs that maximize accessibility...
-
E203.2 Agency Business Needs (Section-by-Section Analysis)
The Board intends, through this provision, to reinforce the fundamental principle that agencies have an affirmative, continuing obligation under Section 508 to maintain the accessibility...
-
Curb Ramps at Marked Crossings and Vehicular Lanes
Access Board’s Note to Reader: The Department of Transportation’s ADA standards require detectable warnings on curb ramps: 406.8 Detectable Warnings....
-
Location of Accessible Parking Spaces
In the final rule, the Board has replaced the reference to "user cost" with "parking fee" which it considered more descriptive....
-
407 Elevators
The Board has revised the rule to reference the most recent edition of this code (105.2.2). The requirements for elevators have been extensively revised and reformatted....
-
307 Protruding Objects
The Board intends to develop guidelines specific to public rights-of-way in a separate rule making....
-
Obstacles [1016.5]
When the surface is constructed of concrete, asphalt, or boards, obstacles cannot exceed one-half inch in height at their highest point....
-
Transfer Access [1014.2.1]
When the surface of the clear ground space is constructed of asphalt, concrete, or boards, the slope of the clear ground space must be no steeper than 1:48 (2 percent) in any direction....
-
C.1. - Who within the agency is responsible for ensuring EIT purchases comply with Section 508?
Acquisition of EIT that meets the applicable technical provisions of the Access Board’s standards is the shared responsibility of requiring activity officials and contracting officials....
-
Model Building Codes and Industry Standards
The Access Board’s 2004 ADA Accessibility Guidelines, upon which the current ADA Standards are based, have been harmonized to a significant extent with industry standards and model building...
-
DOJ’s 2010 ADA Standards for Accessible Design
As implemented under title II, the 2010 Standards consist of the regulatory provisions in 28 CFR §35.151 and appropriate sections of the Access Board’s 2004 ADA Accessibility Guidelines...
-
§ 38.175(a)
., not used by freight trains) or guideway, in which stations are constructed in accordance with part 37, subpart C of this title, shall be designed for high-platform, level boarding and...
-
M305.2.4 Cross Section (Section-by-Section Analysis)
However, in the MDE NPRM preamble, the Access Board noted that it was considering adopting the cross sectional dimensions for grab bars from the 2004 ADA and ABA Accessibility Guidelines...
-
28 CFR Part 36 Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial Facilities NPRM: Preamble (2008 Title III NPRM Preamble)
under the Americans with Disabilities Act of 1990 (ADA) that are "consistent with the minimum guidelines and requirements issued by the Architectural and Transportation Barriers Compliance Board...
-
410.2 Volume Gain (Section-by-Section Analysis)
The Advisory Committee recommended that the Board adopt the FCC’s volume gain requirements for landline ICT with two-way voice communication....
-
§382.3 Battery-powered mobility aid
Battery-powered mobility aid means an assistive device that is used by individuals with mobility impairments such a wheelchair, a scooter, or a Segway when it is used as a mobility device...
-
M305.3.1.1 Horizontal Position
The length of gripping surfaces on horizontal standing supports shall be 4 inches (100 mm) minimum except for diagnostic equipment containing a wheelchair space which shall comply with M305.3.1.2...
-
1133A.2, Item 1
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in a wheelchair shall be provided at the range or cooktop....
-
1002.5.3 Transfer Entry
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
-
§ 36.406(f)(4)
(4) Stadium-style movie theaters shall locate wheelchair seating spaces and companion seating on a riser or cross-aisle in the stadium section that satisfies at least one of the following...
-
1134A.8, Item 3
Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair and the lavatory cabinets are designed with adaptable knee...
-
A4.8.1 General
Ramps are essential for wheelchair users if elevators or lifts are not available to connect different levels....
-
A4.8.1 GENERAL
Ramps are essential for wheelchair users if elevators or lifts are not available to connect different levels....