Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306....
Search Results "Floor Plan"
-
305.4 Knee and Toe Clearance
-
4.18.2 Height
Urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17 in (430 mm) above the finish floor....
-
5f.
Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Stds 4.10.13]...
-
4.2.4 Height of Fire-Building Surface
The fire-building surface within a fire ring shall be at least 9 inches (230 mm) above the floor or ground....
-
4.32.4* HEIGHT OF WORK SURFACES
The tops of tables and work surfaces shall be from 28 in to 34 in (710 mm to 865 mm) from the floor or ground....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
1134A.7, Item 3
The minimum height of water closet seats shall be 15 inches (381 mm) above the floor....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
-
11B-809.10.8.3 Cabinets
The finished floor shall extend to the wall under the lavatory....
-
11B-708.4 Residential dwelling unit communication systems
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with Section 11B-708.4....
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
Maintenance of Accessible Features
Entities should plan for these issues and modify operational policies as needed to provide accessible means of entry while the pool is open....
-
Assessing Your Facility
The purpose of this phase-in period is to provide businesses sufficient time to plan and comply....
-
11B-232.2.1.3 Substitute cells
to provide the required number of cells with mobility features by providing the required mobility features in substitute cells (cells other than those where alterations are originally planned...
-
5.4.1.1 Transfer Support Location Recommendation for Stretchers
(see Figure 5.4.1.1) Figure 5.4.1.1 Transfer Support Location – Plan View (SOURCE: Stryker Medical)...
-
Paperwork Reduction Act
Under this rule, railroads that choose to use a means of meeting the performance standard other than level-entry boarding would have to submit a proposed plan to FRA or FTA demonstrating...
-
A4.33.3 Placement of Wheelchair Locations
The location of wheelchair areas can be planned so that a variety of positions within the seating area are provided. This will allow choice in viewing and price categories....
-
Trail Classes
They are based on forest plan direction and represent intended design and management standards....
-
Organization and Prioritization
The employee may need assistance with skills required to prepare and execute complex behavior like planning, goal setting, and task completion....
-
II. SPECIFIC ACTION TO BE TAKEN BY OLYMPIA:
first notified of the United States’ investigation of Joe Louis Arena, Olympia significantly improved accessibility to the restrooms on the Concourse level by completing its previously-planned...
-
§ 37.43(b)
the maximum extent feasible applies to the occasional case where the nature of an existing facility makes it impossible to comply fully with applicable accessibility standards through a planned...