Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
Search Results "Floor Plan"
-
407.4.6.4.1 Height
-
605 Urinals
Section 604.5 provides criteria for accessible urinals, including the height and depth, clear floor space, and flush controls....
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
-
e-i
Are the centerlines of the call buttons mounted 42 inches above the floor? [ADA Standards § 4.10.3] Yes No...
-
H19
Is the top of the toilet seat 17 inches to 19 inches above the floor? [ADA Standards § 4.16.3] Yes No...
-
Section 2. Single-story dwelling unit
"Single-story dwelling unit" means a dwelling unit with all finished living space located on one floor....
-
Section 2. Loft
"Loft" means an intermediate level between the floor and ceiling of any story, located within a room or rooms of a dwelling....
-
4.18.2 HEIGHT
Urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17 in (430 mm) above the floor....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
Seating Locations
An accessible seating plan requires aisles that are at least 36 inches wide and have sufficient turning space (e.g., a 60-inch diameter circle) in key locations throughout the room. ...
-
Surcharges
The department plans to charge M.N. $250 for the course due to interpreter costs. M.N.’s fee can be no more than the $50 charged other participants....
-
Appalachian Trail Conservancy's "Backcountry Sanitation Manual"
sanitation, including health, aesthetics, and regulations, but it focuses on the construction and maintenance of moldering and composting toilets, and includes case studies and design plans...
-
§ 37.47(e)
(e) A public entity wishing to apply for an extension of the July 26, 1993, deadline for key station accessibility shall include a request for an extension with its plan submitted to FTA...
-
11B-232.2.1.3 Substitute cells
to provide the required number of cells with mobility features by providing the required mobility features in substitute cells (cells other than those where alterations are originally planned...
-
§ 36.401(d)(1)(ii)(B)
The facility housing a "shopping center or shopping mall" only includes floor levels housing at least one sales or rental establishment, or any floor level designed or intended for use by...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Protruding Objects
Wall-mounted objects, with bottom edges between 27 inches and 80 inches above the floor, cannot protrude into the route more than four inches....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
M303.4.1 Breast Platform Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a mammography breast platform height range of 30 inches high minimum and 42 inches high maximum above the floor....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation....
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...