EXCEPTION: Where vehicles are boarded from sidewalks or street-level, low-level platforms shall be permitted to be less than 8 inches (205 mm)....
Search Results "Permitted Transfer"
-
810.5.3 Platform and Vehicle Floor Coordination--Modification to 810.5.3 of Appendix D to 36 CFR Part 1191
-
3. Private Property
., work with the passenger to get the permission of the property owner to permit access for the paratransit vehicle)....
-
1134A.4 Sufficient maneuvering space
The clear maneuvering space shall allow the user to position a wheelchair or other mobility aid clear of the path of the door as it is closed and to permit use of fixtures....
-
11B-307.2 Protrusion limits
Exception: Handrails shall be permitted to protrude 4½ inches (114 mm) maximum. [2010 ADAS] Advisory 307.2 Protrusion Limits. ...
-
11B-411.2.2.1 Visible identification
Exception: Existing buildings shall be permitted to have a visible identification fixture with a car designation character adjacent to each elevator car entrance centered at 72 inches (1829...
-
11B-307.2 Protrusion limits
Exception: Handrails shall be permitted to protrude 4½ inches (114 mm) maximum. Advisory 11B-307.2 Protrusion limits....
-
1134A.4 Sufficient maneuvering space
The clear maneuvering space shall allow the user to position a wheelchair or other mobility aid clear of the path of the door as it is closed and to permit use of fixtures....
-
11B-407.3.4 Door and signal timing
Exceptions: For cars with in-car lanterns, T shall be permitted to begin when the signal is visible from the point 60 inches (1524 mm) directly in front of the farthest hall call button...
-
11B-703.7.2.1 International Symbol of Accessibility
This exception provides latitude in the use of other colors, but artistic license in the graphic representation of the symbol itself is not permitted. ◼...
-
4. Providing Qualified Interpreters and Qualified Readers
vocabulary.8 Similarly, those serving as readers for people who are blind or have low vision must also be “qualified.”9 For example, a qualified reader at an office where people apply for permits...
-
R208.1 Where Required
• Route edges that are clear and detectable by cane; • Direct pedestrian street crossings and curb ramps that are in-line with direction of travel; • Small corner radiuses that permit...
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
ENFORCEMENT
In the event H&R Block seeks to transfer or assign all or part of its interest in any entity covered by this Agreement, and the successor or assignee intends on carrying on the same...
-
Equipment and furniture. (Section-by-Section Analysis)
commenters noted that in recent years, hotel beds have become higher as hotels use thicker mattresses, thereby making it difficult or impossible for many individuals who use wheelchairs to transfer...
-
6. Advance Check-in Time
It also asked about issues passengers who use respiratory assistive devices would face if carriers were permitted to require an advance check-in deadline, as well as what would be a reasonable...
-
1019.1 General
Exceptions to specific provisions in 1011, 1013, 1014, 1015, 1016, 1017, and 1018 shall be permitted when an entity determines that any of the following conditions does not permit full compliance...
-
2. Standing Supports
In addition, the exception permitting only one standing support is conditioned on that support being positioned horizontally in relation to the standing surface, not vertically....
-
1019.1 General
Exceptions to specific provisions in 1011, 1013, 1014, 1015, 1016, 1017, and 1018 shall be permitted when an entity determines that any of the following conditions does not permit full compliance...
-
Background
As a rule, the Building Code requirements that are applicable are the ones that were in effect when the project was permitted....
-
11B-610.3 Shower compartment seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry....
-
Ground Level Requirements Based on Elevated Play Components
The intent of this requirement is to provide a variety of experiences for individuals who choose to remain with their mobility devices, or choose not to transfer to elevated play components...
-
Exercise Equipment and Machines
Clear floor space must be positioned to allow a person to transfer from a wheelchair or to use the equipment while seated in a wheelchair....
-
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS In the absence of Committee consensus commending a departure from the existing broadly accepted transfer surface...