Dimensions of cutout are to be 11" wide x 15-1/2" high (280 x 395mm). Receptacle shall have a capacity of 1.2-gal. (4.6-L). Unit 12 3/4" W, 17 3/16" H, 4 1/16" D (325 x 435 x 105mm)....
Search Results "Minimum Dimension"
- Gamco Partition Mounted Sanitary Napkin Disposal - ND-6
- Better Living LINEA Luxury Soap Dispenser
- Yale 2100 Series Flatbar Exit Device
- Landscape Forms Inc. Presidio Trash Receptacle
- eone Bradley Classic Timepiece
- Caromaยฎ USA Sydney Smart II Elongated Toilet
-
F224.2 Guest Rooms with Mobility Features
[ECTCR UFAS 4.1.4(11)(a) depending on number of guest rooms] Table 224.2 Guest Rooms with Mobility Features Total Number of Guest Rooms Provided Minimum Number of Required...
-
Clear Floor or Ground Space
Clear floor or ground space is also sometimes called "wheelchair parking space." 30-inch (760 mm) by 48-inch (1220 mm) minimum area May overlap accessible routes and maneuvering...
-
F224.5 Dispersion
Where the minimum number of guest rooms required to comply with 806 is not sufficient to allow for complete dispersion, guest rooms shall be dispersed in the following priority: guest room...
-
R214 On-Street Parking Spaces
Table R214 On-Street Parking Spaces Total Number of Marked or Metered Parking Spaces on the Block Perimeter Minimum Required Number of Accessible Parking Spaces...
-
R404 Clear Spaces (Section-by-Section Analysis)
Clear spaces must be 760 millimeters (2.5 feet) minimum by 1220 millimeters (4 feet) minimum....
-
M201.1 Enforcing Authority
The proposed standards do not include scoping requirements that specify the minimum number of types of accessible diagnostic equipment required in different types of health care facilities...
-
ยง 38.159(b)(13) Handrails
Handrails shall have a usable component at least 8 inches (200 mm) long with the lowest portion a minimum 30 inches (760 mm) above the platform and the highest portion a maximum 38 inches...
-
704.3 Volume Control Telephones
Public telephones required to have volume controls shall be equipped with a receive volume control that provides a gain adjustable up to 20 dB minimum....
-
224.5 Dispersion
Where the minimum number of guest rooms required to comply with 806 is not sufficient to allow for complete dispersion, guest rooms shall be dispersed in the following priority: guest room...
- Spectra Safety Treads
-
11B-611.4 Height
Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (381 mm) minimum and 36 inches (914 mm) maximum above the finish floor....
-
F233.3.3 Alterations
residential dwelling unit, the Department of Defense shall be permitted to alter or construct a comparable residential dwelling unit to comply with 809.2 through 809.4 provided that the minimum...
-
611.4 Height
Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (380 mm) minimum and 36 inches (915 mm) maximum above the finish floor....
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
Clear Floor Space
Clear Floor Space The load and unload areas adjacent to ride seats designed for transfer must have a clear space of 30 by 48 inches minimum....
-
R305.2.4 Pedestrian Refuge Islands
At cut-through pedestrian refuge islands, detectable warning surfaces shall be placed at the edges of the pedestrian island and shall be separated by a 610 mm (2.0 ft) minimum length of...
-
C. Food Service
.: direct counter service) at counters or bars, is there a minimum 60" long portion providing a 27" high knee space, at least 19" deep, with the counter top at 28"-34" above the floor, or...