Fire alarms shall comply with F215. EXCEPTION: Fire alarms shall not be required to comply with 702 where existing power sources must be upgraded to meet the requirement....
Search Results "Visual Indicator (Alarm)"
Commonly Searched Documents
-
F202.6.5.2 Fire Alarms
-
11B-407.4.7.1.4 Visible indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
11B-407.4.7.1.4 Visible indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
11B-407.4.7.1.4 Visible indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
407.4.8.2.2 Signal Level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
407.4.8.2.2 Signal Level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
407.4.8.2.2 Signal Level
407.4.8.2.2 Signal Level. The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm signal...
-
Vibrotactile WALK indications
Vibrotactile WALK indications Vibrotactile indications are transmitted by a vibrating plate or arrow on the housing of the pedestrian pushbutton....
-
907.2.6.2.1 System initiation
Actuation of an automatic fire-extinguishing system, a manual fire alarm box or a fire detector shall initiate an approved fire alarm signal which automatically notifies staff....
-
Visible Alarms—Exception to Section 215.1 of the 2010 Standards
Section 215.1 includes a new exception for visible alarms in the alteration of existing facilities, providing that visible alarms must be installed only when an existing fire alarm system...
-
907.2.8 Group R-1
A manual fire alarm system and an automatic fire detection system shall be installed in Group R-1 occupancies....
-
§1193.43(b) Availability of visual information for low vision users
(b) Availability of visual information for low vision users....
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
806.3.1 Alarms
806.3.1 Alarms. Where emergency warning systems are provided, alarms complying with 702 shall be provided....
- Safety Technology: the First 30 Years
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
1.1.3.2, Item 14.3
Fire alarm devices, equipment and systems in connection with any occupancy....
-
702 Fire Alarm Systems
702 Fire Alarm Systems...