11B-702 Fire alarm systems
-
Line Spacing: ADA Standard Section 703.5.9
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
907.5.2.3.5 Groups R-2.1, R-3.1 and R-4
hearing impaired, shall be provided with notification appliances for the hearing impaired installed in accordance with NFPA 72 and which shall activated upon initiation of the fire alarm system...
-
Raised Characters
However, the proposed rule provided a tighter specification (½ to ¾ inch) for raised characters on signs where visual access is provided on a separate sign face because it is believed that...
-
402.2 Speech-Output Enabled
ICT with a display screen shall be speech-output enabled for full and independent use by individuals with vision impairments. EXCEPTIONS: 1....
-
703.5 Visual Characters
Visual characters shall comply with 703.5....
-
215 Fire Alarm Systems
Substantive changes made in the final rule concern existing facilities, work areas, and other types of emergency alarm systems....
-
T704.3.2 Automated Route Identification Announcements
Automated route identification systems shall audibly and visibly identify the fixed route on which the non-rail vehicle is operating....
-
Sec.36.310(c) Requirements for vehicles and systems
(c) Requirements for vehicles and systems....
-
Fire Alarm Systems: ADA Standard Section 702
[See subsections ...]
-
11B-707.7.1 Visibility
Amends technical requirements to correct slope range overlap in requirements for display screens....
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum.
-
11B-703.8.1 General
High resolution variable message sign (VMS) characters shall comply with Sections 11B-703.5 and 11B-703.8.12 through 11B-703.8.14. Low resolution variable message sign (VMS)...
-
Audible Information Systems (slide 14)
This is a quick graphic of a talking signage system. There’s more research that could be done in adding talking signage....
-
Alarms: ADA Standard Section 807.3.1
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with 702 shall be provided....
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
11B-807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided....
-
11B-703.5 Visual characters
Visual characters shall comply with Section 11B-703.5....
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
2.2.1 General Description
2.2.1 General Description There are two types of FM listening systems. One is a personal system, designed to be used by an individual on a one-to-one basis (Yuzon l994)....
-
1007.12 Alarms/emergency warning systems/accessibility
1007.12 Alarms/emergency warning systems/accessibility. If emergency warning systems are required, they shall activate a means of warning the hearing impaired....
-
T704.2 Stop Request Systems
Stop request systems shall comply with T704.3....