Calculations At least 5% of the seating and standing spaces at fixed or built-in dining surfaces provided for the consumption of food or drink must comply with 902 based on TAS 226.2....
Search Results "Standing Support"
Commonly Searched Documents
-
Technical Memorandum TM 2013-14 Dining Surfaces
-
Height
The Access Board is considering whether 6 inches minimum and 19 inches maximum above the transfer surface would be an appropriate height for transfer supports on diagnostic equipment used...
-
Benches
Even if most benches in the amphitheater don't have back support, consider providing it at the designated aisle seats required by ABAAS, section F221.4....
-
5.4.3 Transfer Support Height for M301 and M302
5.4.3 Transfer Support Height for M301 and M302 Description: Transfer support height applies to the vertical distance that the gripping area of the support is above the transfer surface...
-
Clearances Around Gripping Surfaces
The Access Board is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine...
-
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302 Description: Transfer supports may contain elements to provide structural support or prevent patient...
-
M305.2.3 Fittings
M305.2.3 Fittings Proposed requirement: Transfer supports shall not rotate within their fittings • Sub-Committee Recommendation: Transfer supports shall not rotate within their...
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302 Description: A clearance around the gripping surface is necessary to ensure sufficient space for a person...
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302 Description: This minimum distance ensures that the transfer support is within reach of the transfer...
-
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2 Description: This provision prescribes a cross-sectional profile of the transfer support...
-
Radiologic Equipment
Patients may need a staff person to support them with pillows, rolled up towels, wedges, or by holding onto them. Assisted Transfer to Densitometer Utilizing a Stretcher 1....
-
Ticket Prices and Dispersal of Wheelchair Spaces
Paragraph 5 of the "Line of Sight and Dispersion of Wheelchair Spaces in Assembly Areas" section of the Department of Justice's Guidance on the 2010 ADA Standards for Accessible...
-
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual from sufficiently...
-
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
- Project LETS (Let's Erase the Stigma)
- A Complete Guide to Service, Therapy and Emotional Support Dogs
-
Transfer Protocols
For each transfer, participants were asked to position themselves next to the platform as they normally would to prepare for a transfer. The angle of their WMD relative to the front...