Does the 36" x 48" clear floor space directly outside the shower extend at least 12" past the seat wall of the shower to allow for a seat-to-seat transfer from the wheelchair?...
Search Results "Shower Door"
Commonly Searched Documents
-
1d
-
4.21.3 SEAT
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36....
-
4.8.1 General
Outdoor rinsing showers shall provide a hand-held shower spray unit complying with ABAAS section 608.6....
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
1134A.6 Showers
Showers required to be accessible shall comply with this section....
-
407.3 Elevator Door Requirements
407.3 Elevator Door Requirements. Hoistway and car doors shall comply with 407.3....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
404.2.2 Double-Leaf Doors and Gates
404.2.2 Double-Leaf Doors and Gates. At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4....
-
11B-404.2.7 Door and gate hardware
Exceptions: Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles...
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....
-
806 Transient Lodging Guest Rooms
Department’s plans showing accessible transient lodging guest rooms compliant with the 2010 Standards were not common in the transient lodging industry and also noted that the plans omitted doors...
-
Outdoor Rinsing Showers
Outdoor showers permit people to rinse off sand, dirt, and debris. They are not intended for bathing....
-
Automatic Doors
1997 or 2002 editions of ANSI/BHMA A156.19 Power-Assist and Low-Energy Power-Operated Doors....
-
608.2.3 Alternate Roll-In Type Shower Compartments
608.2.3 Alternate Roll-In Type Shower Compartments....
-
604.8.2.2 Doors
604.8.2.2 Doors....
-
Compartment Doors
Specifications are provided for doors, including their location....
-
604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the...