5.3.2 Transfer Sides Recommendations for M301 Description: The transfer side provision requires the transfer surface to be located to provide options to transfer onto the short...
Search Results "Exam Chair"
Commonly Searched Documents
-
5.3.2 Transfer Sides Recommendations for M301
-
5.3.2 Transfer Sides for Equipment Used by Patients in a Supine, Prone, or Side-Lying Position
5.3.2 Transfer Sides for Equipment Used by Patients in a Supine, Prone, or Side-Lying Position.
-
M301.3.1 Transfer Supports
Transfer supports shall be provided for use with the transfer sides required by M301.2.3 and shall comply with M305.2.
-
M301.3 Supports
Transfer supports, stirrups, and reclining surfaces shall comply with M301.3.
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
§ 382.38 Seating accommodations
disability specified in this paragraph, the carrier shall provide the following seating accommodations, subject to the provisions of this section: (1) For a passenger who uses an aisle chair...
-
5.1.3 Transfer Surface Low Height Options for M301 and M302
The Imaging Subcommittee recommended deferring this issue to the Table and Chairs Subcommittee....
- How to: wrap your levers
-
§382.81 For which passengers must carriers make seating accommodations?
As a carrier, you must provide the following seating accommodations to the following passengers on request, if the passenger self-identifies to you as having a disability specified...
-
382.81 For which passengers must carriers make seating accommodations?
382.81 For which passengers must carriers make seating accommodations? ETA Editor's Note This section has no content in the original document.
-
M301.2.3.1 End Transfer Surface
End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. EXCEPTION: Transfer surfaces for imaging equipment with bores shall be...
-
M301.2.3.2 Side Transfer Surface
Side transfer surfaces shall be 28 inches (710 mm) wide minimum and 28 inches (710 mm) long minimum. EXCEPTION: Transfer surfaces for imaging equipment with bores shall be...
-
M301.2.4 Unobstructed Transfer
Each transfer surface shall provide two unobstructed sides for patient transfer. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be permitted to extend beyond...
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M301.4.1 or M301.4.2. EXCEPTION: Where fixed overhead patient...
-
M301.2.4 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as...
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M301.4.1 or M301.4.2.
-
M301.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
§ 36.309(b) Examinations
(b) Examinations.
-
Sec.36.309(b) Examinations
(b) Examinations.
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
How Can You Overcome These Barriers to Work with Your Providers?
There are many things that a person with a disability can do to improve his or her quality of health care and break down the barriers that compromise care. The following suggestions...
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
11B-805.4 Examination, diagnostic and treatment rooms
14, which includes the following interpretation of Section 11B-805.4: Examination, diagnostic and treatment rooms refer to all patient care areas and include but are not limited to: exam...