The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
Search Results "Wheelchair Seating Space"
-
1011.2.3 Slope
- American Standard Cadet 1.1 gpf FloWise Right Height Pressure Assisted Elongated Toilet 2467100
- American Standard Yorkville 1.1 gpf FloWise Right Height Elongated Pressure Assisted Toilet
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...
-
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...
-
1012.3 Other Vehicles
This section requires parking spaces for vehicles, other than recreational vehicles, to be 16 feet wide minimum to accommodate vans equipped with a lift or ramp....
-
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
- Caroma® USA Sydney Smart II Elongated Toilet
-
Work Areas [4.1.1(3)]
Work areas must be accessible for "approach, entry, and exit," which means location on an accessible route so that people using wheelchairs can enter and back out of the space....
-
Clear floor space at Lav
Terry, You should identify the minimum dimensions of the clear floor space at the Lav....
-
222 and 803 Dressing, Fitting, and Locker Rooms
Commenters explained that meeting the new requirement would result in a loss of sales and inventory space....
-
11B-703.3.2 Position
Editor's Note 2013 CBC Figure 11B-703.3.2 is not intended to suggest that Braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-703.3.2 Position
ETA Editor's Note CBC Figure 11B-703.3.2 is not intended to suggest that Braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-703.3.2 Position
Editor's Note CBC Figure 11B-703.3.2 is not intended to suggest that braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
How to Measure Transfer Surface Height
The corner radii allow for closer wheelchair positioning to facilitate independent transfer by minimizing gaps....
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
M302.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum....