Some play components that are attached to a composite play structure can be approached or exited at the ground level or above grade from a platform or deck....
Search Results "Ground Surface"
-
11B-240.2.2 Elevated play components
-
240.2.2 Elevated Play Components
Some play components that are attached to a composite play structure can be approached or exited at the ground level or above grade from a platform or deck....
-
240.2.2 Elevated Play Components
Some play components that are attached to a composite play structure can be approached or exited at the ground level or above grade from a platform or deck....
- BraunAbility UVL Wheelchair Lift for Cutaway Buses and Paratransit Vans
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
Visible Signals: ADA Standard Section 407.2.2.2
Section 407.2.2.2 covers the current ADA Standards for elevator visible signals.
-
Play Tables: ADA Standard Section 1008.4.3
EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
11B-705.1.1.3 Color and Contrast
Detectable warning surfaces shall contrast visually with adjacent walking surfaces either light-on-dark, or dark-on-light. ...
-
11B-705.1.1.3.2
11B-705.1.1.3.2 Detectable warning surfaces shall provide a 70 percent minimum visual contrast with adjacent walking surfaces....
-
11B-705.1.1.3.2
Detectable warning surfaces shall provide a 70 percent minimum visual contrast with adjacent walking surfaces....
-
STEP 2
STEP 2 Determining what is needed based on Table 240.2.1.2: Table 240.2.1.2 Number of elevated play components provided Minimum number of ground-level play components...
-
Transfer Height: ADA Standard Section 1002.5.2
The height of amusement ride seats designed for transfer shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
11B-1002.5.2 Transfer height
The height of amusement ride seats designed for transfer shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
11B-1002.5.2 Transfer height
The height of amusement ride seats designed for transfer shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
R409.4 Height
Top of gripping surfaces of handrails shall be 865 mm (2.8 ft) minimum and 965 mm (3.2 ft) maximum vertically above walking surfaces, ramp surfaces, and stair nosings....
-
Examination Chair
Diagnostic equipment with a seat in which a patient typically is positioned with buttocks approximately parallel to the ground and shins approximately perpendicular to the ground....
-
11B-1009.3.1 Sloped entries
Exception: Where sloped entries are provided, the surfaces shall not be required to be slip resistant....
-
11B-1009.3.1 Sloped entries
Exception: Where sloped entries are provided, the surfaces shall not be required to be slip resistant....
-
11B-240.2.2 Elevated play components
Some play components that are attached to a composite play structure can be approached or exited at the ground level or above grade from a platform or deck....
- Magnuson Group VESUVIO Ash Trays
-
11B-1003.2.1 Boat slips
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7. ...
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
11B-809.12 Electrical receptacles, controls and switches
When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 1/2 inches (650 mm) maximum in depth....