Obstacles are anything that interrupts the evenness of the surface of an ORAR....
Search Results "Transfer Surface"
-
Obstacles [1016.5]
-
R302.7.1 Vertical Alignment
Where pedestrian access routes cross rails at grade, the pedestrian access route surface shall be level and flush with the top of rail at the outer edges of the rails, and the surface between...
-
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS In the absence of Committee consensus commending a departure from the existing broadly accepted transfer surface...
-
3.2 MDE Advisory Committee Process
In all cases except one – the minimum height of transfer surfaces – the Committee reached consensus on the recommended accessibility standards (see Section 5)....
-
1.4 Overview of Report
Section 6 briefly introduces the standard about which Committee members did not reach consensus: the minimum transfer surface height....
-
R208.2 Where Not Required
Detectable warning surfaces are not required at pedestrian refuge islands that are cut-through at street level and are less than 1.8 meters (6.0 ft) in length in the direction of pedestrian...
-
Summary of Results
Therefore, the results can be addressed in terms of a general trend in types of surface materials used....
-
Handrails
Handrails must comply with the following: Clearance between handrail gripping surfaces and adjacent surfaces shall be 1 1/2 inches (38 mm) minimum. ...
-
406.2 Counter Slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20....
-
707.6.3.1 Contrast
Function keys shall contrast visually from background surfaces. Characters and symbols on key surfaces shall contrast visually from key surfaces....
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
Connections [1018.2]
Whenever possible, providing a beach access route that extends into the water will allow people to remain in their mobility devices and to transfer directly into the water....
-
2. Roll-in Shower Size
more than 50 guestrooms/suites, are all required roll-in showers at least 30" wide by 60" long or 36" wide by 60", as configured in Figure 57 below, so persons who use wheelchairs may transfer...
-
Size and Clearances [4.21.2]
Recommendation: Twelve inches of additional clear floor space at the seat will facilitate side transfers....
-
T303.4 Clearance
Clearance between gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
4.34.6.4(5)
(5) There shall be no sharp or abrasive surfaces under such counters. Figure 50 Counter Work Surface...
-
11B-707.6.1 Input controls
Where provided, key surfaces not on active areas of display screens, shall be raised above surrounding surfaces....
-
707.6.1 Input Controls
Where provided, key surfaces not on active areas of display screens, shall be raised above surrounding surfaces....
-
707.6.1 Input Controls
Where provided, key surfaces not on active areas of display screens, shall be raised above surrounding surfaces....
-
11B-707.6.1 Input controls
Where provided, key surfaces not on active areas of display screens, shall be raised above surrounding surfaces....
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
.); and adequate clear floor space inside the room for side transfers and use of lift equipment....
-
11B-707.6.3.1 Contrast
Function keys shall contrast visually from background surfaces. Characters and symbols on key surfaces shall contrast visually from key surfaces....
-
11B-707.6.3.1 Contrast