Section 402.2 covers the current ADA Standards for components of an accessible routes.
Search Results "Comply With"
-
Components: ADA Standard Section 402.2
-
11B-1008.2.1 Ground level and elevated play components
Exceptions: Transfer systems complying with Section 11B-1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided...
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
11B-405.7 Landings
Landings shall comply with Section 11B-405.7. Advisory 11B-405.7 Landings....
-
Ground Level and Elevated Play Components: ADA Standard Section 1008.2.1
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided no more than 25 percent of the...
-
11B-306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with Section 11B-306....
-
11B-810.6.3 Station names
Stations covered by this section shall have identification signs complying with Section 11B-703.5....
-
11B-306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with Section 11B-306....
-
M302.2.5 Unobstructed Transfer
Each transfer side complying with M302.2.4 shall provide unobstructed access to transfer surfaces. EXCEPTIONS: 1....
-
604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
1002.4.4 Clearances
Clearances for wheelchair spaces shall comply with 1002.4.4. EXCEPTIONS: 1. Where provided, securement devices shall be permitted to overlap required clearances. 2....
-
Water Play Components
Water Play Components If water play components are provided, they must comply with the Access Board’s Play Area Guidelines and accessible route provisions....
-
405.8 Handrails
Ramp runs with a rise greater than 6 inches (150 mm) shall have handrails complying with 505....
-
Existing Trailheads [F202.3]
At existing trailheads, if elements or spaces are altered but the circulation path to the altered space or element is not changed, the circulation path does not have to be altered to comply...
-
Outdoor Constructed Features at Trailheads [F247.3.1 and 1011]
features, such as benches, picnic tables, or trash and recycling receptacles, are provided at trailheads, at least 20 percent, but no less than one, of each type of element provided must comply...
-
R308.1.1 Boarding and Alighting Areas
Boarding and alighting areas at sidewalk or street level transit stops shall comply with R308.1.1 and R308.1.3....
-
1014.2.2 Roll-in Access
Where roll-in access is provided, this section requires a level or sloped entry route complying with the technical requirements for outdoor recreation access routes in 1016 or trails in...
-
Stairways [ADA Standards §210, §504]
In addition, interior and exterior stairs that are part of a means of egress must comply with requirements in the ADA Standards (§504)....
-
§ 38.111(a)(2)
(2) Single-level dining and lounge cars shall have at least one connecting doorway complying with §38.113(a)(2) of this part connected to a car accessible to persons using wheelchairs or...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be integrated...
-
11B-206.4.7 Restricted entrances
Where restricted entrances are provided to a building or facility, all restricted entrances to the building or facility shall comply with Section 11B-404....
-
1018.2 Aisles in assembly spaces
Aisles and aisle accessways serving a room or space used for assembly purposes shall comply with Section 1029....
-
§ 38.95(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section; sufficient clearances to permit a wheelchair or mobility aid user to reach a seating location;...
-
§ 38.113(b) Passageway
paragraph (a) of this section shall permit access by persons using mobility aids and shall have an unobstructed passageway at least 32 inches wide leading to an accessible sleeping compartment complying...