An accessible table has a surface height of no more than 34 inches and no less than 28 inches above the floor....
Search Results "Floor Surface"
-
Fixed Seating and Tables
-
An accessible route must connect the wheelchair seating locations with the stage(s), performing areas, arena or stadium floor, dressing or locker rooms, and other spaces used by performers.
• An accessible route must connect the wheelchair seating locations with the stage(s), performing areas, arena or stadium floor, dressing or locker rooms, and other spaces used by performers...
-
11B.707.7.1.3 Horizontally mounted display screen
and no more than 90 degrees (horizontal) tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
Preserving elevator access in building where it might not be required.
However, the building has an elevator, which currently provides access to all 6 floors and a mezzanine between the first and second floors. ...
-
Alterations
Where play components are altered and the ground surface is not, the ground surface does not have to comply with the ASTM F 1951-99 standard for accessible surfaces unless the cost of providing...
- ADA Solutions, Inc. Surface Applied Truncated Dome Detectable Warning Systems Video
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device. The clear space shall extend under the bed parallel to the long side and be adjacent to an...
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device. The clear space shall extend under the bed parallel to the long side and be adjacent to an...
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device. The clear space shall extend under the bed parallel to the long side and be adjacent to an...
- SmartCells Flooring: Infection Control Demonstration
- SmartCells Flooring: Anti-Fatigue Matting
- AJW Architectural Products US52 Collapsable Security Hook Strip & Shelf 18"L, 4 Hooks, Exposed Mounting - Surface Mounted
-
§ 38.23(b)(7) Platform gaps
Any openings between the platform surface and the raised barriers shall not exceed 5/8 inch in width....
-
1132A.4, Item 2
., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor...
-
502.6 Identification
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign....
-
1132A.4, Item 2
., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor...
-
308.3.1 Unobstructed
reach shall be 15 inches (380 mm) minimum above the finish floor or ground....
-
809.2.2 Turning Space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
809.2.2 Turning Space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
809.2.2 Turning Space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
Test Procedures
The procedures are based on the draft national standard test method for the firmness and stability of ground and floor surfaces (RESNA 2000), which uses an average of five readings....
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...