An expansion, extension, or increase in the gross floor area of a building or facility....
Search Results "Floor Slope"
-
ADDITION
-
11B-233.3.1.2.1 Elevator buildings
Residential dwelling units on floors served by an elevator shall be adaptable....
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
Extensions
Extensions must be rounded or returned to the walls, floors, or posts....
-
4.8.1 General
One fixed showerhead shall be 48 inches (1220 mm) above the floor or ground surface, and one fixed shower head shall be 72 inches (1830 mm) minimum above the floor or ground surface....
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
1004 Exercise Machines
This section requires clear floor space for transfer to, or use of, exercise machines....
-
Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
106.5.3 Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
Spy City Café
bottom edges of the reflecting surfaces of the mirrors in the men's and women's toilet rooms located outside the Café and designated as accessible are mounted 57 ½" [sic] from the finished floor...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
Platform Size and Surface
In addition, changes in level between ¼ to ½ inch must be beveled with a slope 1:2 maximum; changes in level more than ½ inch must be treated as a ramp....
-
Curb Ramps
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, it shall have flared sides; the maximum slope of the flare...
-
406.7 Islands
Each 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the curb ramp it...