2-piece ramp in folding suitcase style Load capacity: 350-lb per side, 700-lb combined Full size: 7' long x 29.75" wide Folded suitcase size: 46" long x...
Search Results "PLZ Access Aisle"
- Nova Health Products LiteRamp 7' Wheelchair and Scooter Ramp (LR7)
- Amramp Portable Ramps
- Harmar CPL400P Portable Vertical Platform Lift
- Nova Health Products LiteRamp 6' Wheelchair and Scooter Ramp (LR6)
- Nova Health Products LiteRamp 8' Wheelchair and Scooter Ramp (LR8)
- American Safety Tread Co., Inc. Type G500R Stairway Nosing Replacement
- American Safety Tread Co., Inc. Type SG4702 Stairway Nosing Replacement
- American Safety Tread Co., Inc. Type G4702 Stairway Nosing Replacement
-
Guidelines for Requirement 2
parking code requires greater accessibility features (e.g. wider aisles) with respect to parking and passenger loading zones, the appropriate provisions of the local code would prevail....
-
11B-216.7 Elevators
Where existing elevators do not comply with Section 11B-407, elevators complying with Section 11B-407 shall be clearly identified with the International Symbol of Accessibility complying...
-
11B-216.7 Elevators
Where existing elevators do not comply with Section 11B-407, elevators complying with Section 11B-407 shall be clearly identified with the International Symbol of Accessibility complying...
-
1009.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with the emergency operation and signaling device requirements of California Code of Regulations...
-
11B-216.7 Elevators
Where existing elevators do not comply with Section 11B-407, elevators complying with Section 11B-407 shall be clearly identified with the International Symbol of Accessibility complying...
-
604.8.1.4 Toe Clearance
[ECTCR UFAS 4.17.4] Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
604.8.1.4 Toe Clearance
Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
11B-502.6.4.1
The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide by 36 inches high...
-
1016.6 Openings
This section requires openings in the surface of outdoor recreation access routes, passing spaces, and resting intervals such as spaces between the boards in a boardwalk and drainage grates...
-
4.10.1 GENERAL
Accessible elevators shall be on an accessible route and shall comply with 4.10 and with the American National Standard Safety Code for Elevators, Dumbwaiters, Escalators, and Moving Walks...
-
11B-502.6.4.1
The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide by 36 inches high...
-
11B-502.6.4.1
11B-502.6.4.1 The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide...
-
2016 California Standards for Accessible Design
[See subsections ...]
-
6.5 Surface
The surface of beach access routes and their related resting intervals shall be firm and stable....
-
A. Electronic Content
The existing requirement does not adequately address what is meant by comparable access to information and data....
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the...