narrowed width permitted for 24-inch (610 mm) length to accommodate features in the composite structure 12-inch (305 mm) rise maximum per ramp run Top of handrail gripping surfaces...
Search Results "Trail Surface"
Commonly Searched Documents
-
Elevated Accessible Routes
-
Play Tables
Play Tables Play tables are surfaces, boards, slabs, or counters that are created for play....
-
809.2.2 Turning Space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
Technical Memorandum TM 2012-04 Multi-Story Buildings and Facilities
The term “story” is defined in 106.5.64 as that portion of a building or facility designed for human occupancy included between the upper surface of a floor or the upper surface of the floor...
-
809.2.2 Turning Space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
REFERENCES
., Proposed Surface Roughness Standard for Pathways used by Wheelchairs. Transportation Research Board 93nd Annual Meeting, 2014(14-4494). 5....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position; M302 Diagnostic Equipment Used by Patients in Seated Position
Except for the size of the transfer surface (see M301.2.2 and M302.2.2) and certain supports (see M301.3.2 for stirrups, and M302.3.2 for armrests), the technical criteria in these sections...
-
§ 38.95(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
§ 38.125(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
§ 38.83(b)(13) Handrails
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
-
11B-505.10.3 Bottom extension at stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
APPENDIX A. GUIDELINES FOR SERVICE ANIMAL RELIEF AREAS (SARA)
A.4 Surfaces. A relief area should have at least two different surfaces. One should be hard and located immediately inside the entrance to allow wheelchair access....
-
11B-707.6.3.2 Tactile symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
705.1.1 Dome Size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum...
-
1007 Miniature Golf Facilities
This section covers miniature golf courses and contains specifications for accessible routes that take into account design conventions for miniature golf courses, such as carpeted play surfaces...
-
707.6.3.2 Tactile Symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
1009.2.2 Seat Location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48. Figure 1009.2.2 Pool Lift Seat Location...
-
707.6.3.2 Tactile Symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
1018.6 Openings
Openings in the surface of beach access routes and resting intervals shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1018.6 Openings. ...
-
705.1.1 Dome Size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum...
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
1132A.4, Item 2
wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor surfaces...
-
1018.6 Openings
Openings in the surface of beach access routes and resting intervals shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1018.6 Openings....