◼ Checklist for Facility MAINTENANCE Responsibilities (11/16/00) Click here to view or download the "Checklist for Facility MAINTENANCE Responsibilities" (20 KB pdf)
Search Results "TAAC: Telecommunications Access Advisory Committee"
Commonly Searched Documents
-
Checklist for Facility MAINTENANCE Responsibilities
-
Door Opening Force
Door Opening Force If you’re using a door pressure gauge, place it where you would push open the door. If you’re using a fish scale, place it...
-
How to Use this Checklist
Get Organized One person can conduct a survey, but it’s easier with two people. One person can take measurements and the other person can fill out the checklist and take...
-
12162(a)(2)(D)(i)
(i) be able to be entered by an individual who uses a wheelchair;
-
§ 36.302(f)(4)(iii) Sales limited to fewer than four tickets
(iii) Sales limited to fewer than four tickets. If a public accommodation limits sales of tickets to fewer than four seats per patron, then the public accommodation is only obligated...
-
§ 36.302(f)(4)(i) General
(i) General. For each ticket for a wheelchair space purchased by an individual with a disability or a third-party purchasing such a ticket at his or her request, a public...
-
2004 ADA Checklist for Polling Places
ADA Checklist for Polling Places February 2004 Reproduction The ADA authorizes the Department of Justice to provide technical assistance to individuals and entities...
-
6. MEDICAL CARE FACILITIES
[See subsections ...]
-
6.1 General
Medical care facilities included in this section are those in which people receive physical or medical treatment or care and where persons may need assistance in responding to an...
-
6.8.2 Grade and cross slope
The slope of a resting interval shall not be steeper than 1:33 (3 percent) in any direction. Where the surface is paved or is elevated above the natural ground, the surface shall not...
-
3.2.5.1 Walk-In Camping
Where walk-in camping is provided, an ORAR connecting the camp living area to the parking area shall be provided in accordance with section 2.0.
-
2.2 Surface
The surface of an ORAR shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
6.1 GENERAL
In addition to the requirements of 4.1 to 4.33, Health Care buildings and facilities shall comply with 6.
-
1018.8.2 Slope
This section requires the slope of resting intervals to not be steeper than 1:48 in any direction. Where the surface is other than asphalt, concrete, or boards, slopes not steeper...
-
2.5.1 Location
A resting interval shall be provided between each ORAR segment, in compliance with section 2.4.1. Depending on the design and location, the intersection of two ORARs may act as a...
-
2.4.2 Cross Slope
The cross slope of an ORAR shall be no more than 1:33 (3 percent). Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48...
-
Door Pressure Gauge
Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, measures forces from 0-35 pounds on one side and 0-16 kilograms on the other. If you do not...
-
Double Action Door Pressure Gauge
Double Action Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, has Push-Pull capability and measures forces from 0-35 pounds on one side and...
-
Note Regarding Comparative Table
For the convenience of the reader, the Appendix to this document provides a table that lists in column one the exceptions contained in the document and in the second column, the UFAS...
-
4.1.1(6)
(6) If toilet facilities are provided on a site, then each such public or common use toilet facility shall comply with 4.22. If bathing facilities are provided on a site, then each...
-
1018.8.2 Slope
Resting intervals shall have a slope not steeper than 1:48 in any direction. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than...
-
1014.2.1.1.1 Surface
The surface of the clear ground space shall be firm and stable.
-
1016.7.2 Cross Slope
The cross slope shall not be steeper than 1:48. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when...
-
Raised Crossings
Raised crossings, where provided, eliminate the need for curb ramps while serving to reduce traffic speeds. Consult local Standards for application requirements, including slope...