Paragraph (f) Prevention of visually induced seizures (Section-by-Section Analysis)
The Epilepsy Foundation of America suggested that the value be reduced to a maximum 2 Hz, based on recent suggested changes to ADAAG and the ANSI A117.1 accessibility standard....
-
Operable Parts of Windows
The Board sought comment on whether a maximum sill height should be specified so that people who use wheelchairs can look through the window to view ground level activities (Question 16)...
-
Plan 6B: 12-Foot Wide Accessible Guest Room
Features include a transfer shower, water closet length (rim to rear wall) 24 inches maximum, comparable vanity, wardrobe, and door connecting to adjacent guest room....
-
Handrails
The Board has removed as redundant an exception in the handrail section for ramps with a rise of 6 inches maximum (505.2, Exception 2)....
-
Accessible Counter Height
Where only a portion of a counter is made accessible, these commenters advised that the maximum height should be 32 inches....
-
11B-702.1 General
have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1), except that the maximum...
-
11B-703.3.2 Position
Braille shall be separated 3/8 inch (9.5 mm) minimum and ½ inch (12.7 mm) maximum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements...
-
11B-406.5.3 Landings
The slope of the landing in all directions shall be 1:48 maximum. [Safe Harbor only applies to existing curb ramps in the vicinity of, and leading to, a primary entrance.]...
-
Toilet Paper Dispensers
effectively preclude some dispensers from being located above grab bars in view of the minimum mounting height of grab bars (33 inches, measured to the top of the gripping surface) and the maximum...
-
606.2 Clear Floor Space
minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31 inches (785 mm) maximum...
-
1117B.2.8
Such telephones shall be capable of a minimum of 12 dBA and a maximum of 18 dBA above normal. If an automatic reset is provided, 18 dBA may be exceeded....
-
1012.3 Opening limitations
Exceptions: The triangular openings formed by the riser, tread and bottom rail at the open side of a stairway shall be of a maximum size such that a sphere of 6 inches (152 mm)...
-
Ground-Level Accessible Routes
Ground-Level Accessible Routes A ground-level accessible route connects play components at ground level. 60 inches (1525 mm) minimum clear width 1:16 maximum slope ...
-
Alterations
The seat of at least one spring rocker is between 11 inches (280 mm) and 24 inches (610 mm) maximum, and clear floor or ground space and maneuvering space is provided. ...
-
606.2 Clear Floor Space
minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31 inches (785 mm) maximum...
-
R204.4 Pedestrian Overpasses and Underpasses
Where the pedestrian access route is not contained within the street or highway right-of-way, the grade of the pedestrian access route must be 5 percent maximum (see R302.5)....
-
606.2 Clear Floor Space
minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31 inches (785 mm) maximum...
-
Trail Facilities
As explained in "Camp Shelters" of this guidebook, this can be accomplished by ensuring the camp shelter floor is 17 inches (430 millimeters) minimum to 19 inches (485 millimeters) maximum...