Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
Search Results "Input Floor"
Commonly Searched Documents
-
4.10.3 Hall Call Buttons
-
4.13.9* Door Hardware
Hardware required for accessible door passage shall be mounted no higher than 48 in (1220 mm) above finished floor....
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
Safety Considerations for Site Selection
When possible, request meeting rooms on the ground floor with direct accessible paths to the outside....
-
Slope [4.3.7]
Requirements in 4.3, while based on the expectation of level floors, apply equally to exterior sites....
-
4.30.6 Mounting Location and Height
Mounting height shall be 60 in (1525 mm) above the finish floor to the centerline of the sign....
-
4.10.6* DOOR PROTECTIVE AND REOPENING DEVICE
device shall be capable of completing these operations without requiring contact for an obstruction passing through the opening at heights of 5 in and 29 in (125 mm and 735 mm) from the floor...
-
11B-1008.4.3 Play tables
Exception: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
11B-809.7 Accessible routes
The accessible route shall adjoin or overlap clear floor spaces and connect all exterior doors....
-
11B-1008.4.3 Play tables
Exception: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
- Ascension Virtuoso 5460F Vertical Permanently-Installed Wheelchair Lift
- Hoyer Advance-E Power Lift
-
Auditorium accessible seating
Graphically one wheelchair floor space takes up two rows so you are probably looking at a 60” deep floor space. ...
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
The in-swinging door increases overall room size because it cannot swing over the required clear floor space at any accessible fixture, (see section 4.22.2 of the 1991 Standards)....
-
Components (M303.4)
M303.4.1 would require the height of the breast platform to be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when mammography equipment is used by...
-
Weight Scales
Unit costs are presented for wheelchair scales with raised platforms and with flush platforms in the floor....
- Access-Able Designs Stationary Dressing Bench DST-101
-
Why a smooth surface door or kickplate is important
This video shows what can happen if the push side of a door near the floor isn't smooth. ...
- AD Systems’ Exam Room Doors
- DORMA BTS80 EMB Series Door Closer
-
Toilet Buildings and Pit Toilets
Provide a clear floor space that is at least 60 inches (1,525 millimeters) wide and 56 inches (1,420 millimeters) deep around the toilet....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....