Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
Search Results "Accessible Seating"
-
M303.3.3 Ramped
-
M302.4.1 Clearance in Base
The base of the diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep...
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms.
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height. Edge protection is not required on platforms 1 ½ inches or less in height.
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms Recommendations Description: Entry to wheelchair spaces on raised surfaces greater than ¼ inch in height requires a...
-
5.8.1.2.1 Ramped Entry Slope
5.8.1.2.1 Ramped Entry Slope. Raised platforms should have a ramp with slopes that do not exceed the following: Rise 0 to 1 ½ inches – 1:2 Slope Rise >1 ½ to 2 ½ inches – 1:8...
-
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides. A minimum 2 inch high edge protection must be provided on both sides of the platform for double ramped entry...
-
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides. A 2 inch high edge protection must be provided on the back of the platform, opposite the entry...
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations The Committee recommends that no edge protection be required on platforms of 1½ inches or less...
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side.
-
M302.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
§ 38.75(c)
(c) Characters on signs required by paragraphs (a) or (b) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and...
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
Section 504 of the Rehabilitation Act
The Department of Justice requires facilities designed, constructed, or altered by recipients of federal financial assistance to be accessible to individuals with disabilities....
-
§8.21(c)(2)(i) General
recipient may comply with the requirements of this section in its programs and activities receiving Federal financial assistance through such means as location of programs or services to accessible...
-
Temporay Concert Accessibility
They have permanent seating in bleachers with accessible seating as required, etc. ...
-
Beach Nourishment
An entity is not required to expend more than 20% of the costs of a beach nourishment project to provide a beach access route....
- Virtuoso Portable Wheelchair Lift 5460P
-
11B-604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....
-
604.8.2.1 Size