The standards specify a maximum height (27”) for the leading edge of barriers so they are within cane sweep, but a minimum height is not specified....
Search Results "Minimum Dimension"
-
Can curbs be used to indicate areas with less than 80” of vertical clearance?
-
Reason the Access Board is issuing the proposed standards
Section 510 of the Rehabilitation Act (29 USC 794f) requires the Access Board, in consultation with the Commissioner of the Food and Drug Administration, to issue standards that contain minimum...
-
11B-1008.2 Accessible routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches (2032 mm) high minimum....
-
§ 38.93(b) Passageways
In cars where such doorways require passage through a vestibule, such vestibule shall have a minimum width of 42 inches. (See Fig. 3.)...
-
11B-1008.2 Accessible routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches (2032 mm) high minimum....
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
1009.2.2 Seat Location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
- Viking E-1600A-BLT-EWP Emergency Tower Phone with Blue LED Beacon and Strobe Light
-
12204(c)(3) Other sites
guidelines described in paragraph (1) shall establish procedures equivalent to those established by 4.1.7(1) (b) and (c) of the Uniform Federal Accessibility Standards, and shall require, at a minimum...
-
§1607.14 Technical standards for validity studies.
The following minimum standards, as applicable, should be met in conducting a validity study....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
[F] 907.5.2.3.2 Employee work areas
Where employee work areas have audible alarm coverage, the notification appliance circuits serving the employee work areas shall be initially designed with a minimum of 20-percent spare...
-
404.2.4 Maneuvering Clearances
Minimum maneuvering clearances at doors and gates shall comply with 404.2.4....
-
F233.4.3 Additions
residential dwelling units, the requirements of F233.4.1 shall apply only to the residential dwelling units that are added until the total number of residential dwelling units complies with the minimum...
-
1016.8.2 Width
Where resting intervals are provided adjacent to an outdoor recreation access route, the resting interval shall be 36 inches (915 mm) wide minimum....
-
605.2 Height and Depth
Urinals shall be 13½ inches (345 mm) deep minimum measured from the outer face of the urinal rim to the back of the fixture....
-
Clear Floor or Ground Space
Clear Floor or Ground Space At least one clear floor or ground space (30 inches by 48 inches minimum) must be provided at each location that has a railing height of 34 inches maximum....
-
Transfer Platform
Platforms must be a minimum of 19 inches deep by 24 inches wide....
-
502.5 Vertical Clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. Advisory 502.5 Vertical Clearance....
-
F233.3.2 Additions
residential dwelling units, the requirements of F233.3.1 shall apply only to the residential dwelling units that are added until the total number of residential dwelling units complies with the minimum...
-
804.3.2 Height
EXCEPTION: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted....
-
Adjustable height/gap protocol
The maximum and minimum heights attainable with the largest horizontal distance were recorded. ...
-
12204(c)(3) Other sites
guidelines described in paragraph (1) shall establish procedures equivalent to those established by 4.1.7(1)(b) and (c) of the Uniform Federal Accessibility Standards, and shall require, at a minimum...