Their experienced immigration lawyers assess each case carefully and provide practical solutions based on UK Home Office guidelines....
Search Results "Maximum Extent Practicable"
-
Trusted Immigration Support and Legal Guidance in London
-
Title III Readily Achievable Barrier Removal
., hotels, resorts, swim clubs, and sites of events open to the public) remove physical barriers in existing pools to the extent that it is readily achievable to do so (i.e., easily accomplishable...
-
‘‘Private club.’’ (Preamble, Section-by-Section Analysis)
Title II of the 1964 Act exempts any ‘‘private club or other establishment not in fact open to the public, except to the extent that the facilities of such establishment are made available...
-
Private club (Section-By-Section Analysis and Response to Comments)
Title II of the 1964 Act exempts any "private club or other establishment not in fact open to the public, except to the extent that the facilities of such establishment are made available...
-
Section 36.207 Places of Public Accommodation Located in Private Residences (Preamble, Section-by-Section Analysis)
Paragraph (b) was added in response to comments that sought clarification on the extent of coverage of the private residence used as the place of public accommodation....
- Panda TS.83 Thermally Broken Multi-Slide Door System
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
Cross Slope
Cross Slope The cross slopes of gangways, transition plates and floating piers that are part of an accessible route must be designed and constructed not to exceed a maximum of 2 percent...
-
Dispersion
To provide anglers with disabilities similar opportunities, the accessible 34-inch maximum railing must be located in a variety of places on the pier or platform to offer a variety of locations...
-
Toilet Rooms-Banquet Area
The force required to push or pull open the doors to the women's and men's toilet rooms designated as accessible is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf...
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
-
Passing Spaces (R302.4) (Section-by-Section Analysis)
Section-by-Section Analysis) Where the clear width of pedestrian access routes is less than 1.5 meters (5 feet), passing spaces must be provided at intervals of 61 meters (200 feet) maximum...
-
R407.2 Running Slope
Ramp runs shall have a running slope between 5 percent minimum and 8.3 percent maximum. Advisory R407.2 Running Slope....
-
1134A.6, Item 5
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
-
4.7.5 SIDES OF CURB RAMPS
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, then it shall have flared sides; the maximum slope of the...
-
Post-Mounted Objects [§307.3]
Objects with leading edges 27” maximum or above 80” can protrude any amount from posts or pylons....
-
1134A.6, Item 5
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
-
§ 38.159(b)(10) Platform movement
The maximum platform horizontal and vertical acceleration when occupied shall be 0.3g....
-
§ 38.153(c)(1)
The clear width may be reduced by a maximum of 4 inches (100 mm) by protrusions of hinges or other operating mechanisms....
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
COMMERCIAL PLACE OF PUBLIC AMUSEMENT
[DSA-AC] An auditorium, convention center, cultural complex, exhibition hall, permanent amusement park, sports arena, theater or movie house for which the maximum occupancy is 2,500 or more...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....