(15) Installing a raised toilet seat;...
Search Results "Single User Toilet Room"
-
Sec.36.304(b)(15)
-
§ 36.304(b)(15)
(15) Installing a raised toilet seat;...
-
GRAB BAR
A grab bar may also provide support for a user transferring from a wheelchair onto a bench, seat or plumbing fixture. ◼...
-
GRAB BAR
A grab bar may also provide support for a user transferring from a wheelchair onto a bench, seat or plumbing fixture. ◼...
-
CLEAR FLOOR SPACE
[DSA-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
§100.10(c)(1)(i)
(i) The owner does not own or have any interest in more than three single family houses at any one time....
-
302.8 With Limited Reach and Strength (Section-by-Section Analysis)
The existing 508 Standards address the needs of users with limited manipulation and users with limited reach or strength in the same criterion (see § 1194.31(f))....
-
Check-In and Check-Out Procedures
Room Keys. Use of a passcard-type room key may be difficult for a guest who is blind or who has low vision....
-
Common Use
Interior or exterior circulation paths, rooms, spaces, or elements that are not for public use and are made available for the shared use of two or more people....
-
11B-1009.2.9 Lifting capacity
Single person pool lifts shall have a weight capacity of 300 pounds (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
11B-1009.2.9 Lifting capacity
Single person pool lifts shall have a weight capacity of 300 pounds (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
11B-1009.2.9 Lifting capacity
Single person pool lifts shall have a weight capacity of 300 pounds (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
1009.2.9 Lifting Capacity
Single person pool lifts shall have a weight capacity of 300 pounds. (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
When do path of travel and/or accessible routes apply? …new construction? …alterations to a parking area? …alterations to a building associated with parking, such as expansion or remodel?
In the new construction of a new facility, all accessible rooms and spaces are required to be connected by an accessible route and all toilet facilities, drinking fountains, public telephones...
- Variety Freedom Program
-
§ 36.302(f)(2) Identification of available accessible seating
A public accommodation that sells or distributes tickets for a single event or series of events shall, upon inquiry—...
-
A4.15.2 Spout Height
Two drinking fountains, mounted side by side or on a single post, are usable by people with disabilities and people who find it difficult to bend over....
-
4.1.6(1)(c)
(c) If alterations of single elements, when considered together, amount to an alteration of a space of a building or facility, the entire space shall be made accessible....
-
CLEAR FLOOR SPACE
[DSA-AC & HCD 1-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
§ 35.138(b) Identification of available accessible seating
A public entity that sells or distributes tickets for a single event or series of events shall, upon inquiry—...
-
CLEAR FLOOR SPACE
[DSA-AC & HCD 1-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
Sec.36.304(b)(12)
(12) Installing grab bars in toilet stalls;...
-
§ 36.304(b)(12)
(12) Installing grab bars in toilet stalls;...
-
General Tips
If service counters are too high for some users, such as people of short stature and people using wheelchairs, step around counters to provide service....