is connected by an aisle with a minimum clear width of 30 inches to one or more spaces where wheelchair or mobility aid users can be accommodated, then such doorway shall have, to the maximum...
Search Results "Maximum Reach Depth"
-
§ 38.93(a)(2)
-
11B-812.5.4 Arrangement
Vehicle spaces installed in existing facilities shall comply with Section 11B-812.5.4 to the maximum extent feasible....
-
11B-505.5 Clearance
Handrails may be located in a recess if the recess is 3 inches (76 mm) maximum deep and 18 inches (457 mm) minimum clear above the top of the handrail....
-
608.3.2 Standard Roll-In Type Shower Compartments
Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter "I"....
-
1. Thigh Breadth
The 95th percentile and maximum values across the 6 sub-groups were within a range of 22in-28in, and the maximum values were within the 26in-30in. range....
-
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
disabilities to firmly grasp the grab bars and support themselves during transfers: Grab bars with circular cross sections must have an outside diameter of 1¼ inches minimum and 2 inches maximum...
-
Newly Constructed Tabled Intersections That Contain Pedestrian Street Crossings With Yield or Stop Control (Section-by-Section Analysis)
Newly Constructed Tabled Intersections That Contain Pedestrian Street Crossings With Yield or Stop Control (Section-by-Section Analysis) The 2 percent maximum cross slope requirement...
-
Addendum F: Relative Height Differences
Adjustable Height No Grab Bars/No Backrest Maximum Height (n=71) .300 3.5 5.00 9.00 13.7...
-
11B-809.8 Doors
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 4 inches (102 mm)....
-
Adjustable Height Range Considered
The technical criteria allow the height of transfer surfaces to be either fixed or adjustable within the 17 inches minimum and 19 inches maximum range....
-
Trail Study Sites
Nearer the waterline the slope of the path increased to a maximum of approximately 5% for the final few meters (feet)....
-
11B-1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
1134A.8, Item 1
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor....
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”. ...
-
407.4.8.2.1 Signal Type
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum...
-
§8.6(c)
result in such an alteration or burdens, the recipient shall take any other action that would not result in such an alteration or such burdens but would nevertheless ensure that, to the maximum...
-
11B-405.3 Cross slope
Curved ramps are not prohibited by Chapter 11B; however, requirements for maximum slope and cross-slope cannot be exceeded. ◼...
-
4.34.6.5(1)
(1) The sink and surrounding counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable...
-
Handrails [§504.6, §505]
Stairway Handrails Recommendation: In facilities that primarily serve children, a second set of stairway handrails 28” high maximum above stair nosings is advisable....
-
1.1.3 Walk running slope
Measure for overall running slope (the primary direction of travel) by determining elevations at the ends of the walk, noticeable changes in slope, or at a maximum of 20 ft (6 m) intervals...
-
1134A.8, Item 1
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor....
-
11B-812.7.2 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center....