The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception of imaging equipment....
Search Results "Strength Equipment"
-
5.2.1.2 Transfer Surface Depth
-
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
M302.3.2 Leg Supports (Section-by-Section Analysis)
The MDE NPRM did not propose to require stirrups to provide a method of supporting, positioning, and securing the patient’s legs for diagnostic equipment used by patients in the seated position...
-
C201.5 Design, Development, and Fabrication
Telecommunications equipment manufacturers shall evaluate the accessibility, usability, and interoperability of ICT during its product design, development, and fabrication....
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
A. Chapter 1: Application and Administration (Section-by-Section Analysis)
The Access Board made a few editorial changes to some of the provisions, and added one provision M101.3 Existing Diagnostic Equipment, which is discussed below....
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
5.2.1.1 Transfer Surface Width Recommendations for M301
Currently, the only equipment existing with a 30-inch transfer surface width is bariatric equipment. At the Committee’s December 2012 meeting, Dr....
-
M301.2.1 Transfer Surface Height
Most tables for use with equipment for bores are height adjustable....
-
5.2.1 Transfer Surface Size Recommendations for M301
5.2.1 Transfer Surface Size Recommendations for M301 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids transfer...
-
M101.2 Application
The standards shall be applied to diagnostic equipment based on the patient positions that the equipment is designed to support....
- Cybex Treadmills
-
Regulatory Flexibility Act
In particular, the certification noted that manufacturers of telecommunications equipment and customer premises equipment are required to comply with section 255 of the Telecommunications...
-
C201.1 Scope
Manufacturers of telecommunications equipment shall comply with the requirements in the 255 Guidelines applicable to such equipment when newly released, upgraded, or substantially changed...
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position....
-
4.5 Other Tips for Making Equipment More Useable
Unless you are very familiar and comfortable with the equipment, you should ask the staff to show you the types of equipment and how they work....
-
Section 1193.23 Product design, development and evaluation (Section-by-Section Analysis)
and customer premises equipment and incorporate such evaluation throughout product design, development, and fabrication, as early and consistently as possible....
-
2. Equipment Clearances for Breast Platforms
Additionally, this commenter raised concerns that mammography equipment must have a stabilizing flange or foot at its base to prevent the equipment from tipping when the gantry is extended...
-
M301.1 General
Where diagnostic equipment is used by patients in a supine, prone, or side-lying position, it shall comply with M301....
- Senographe Essential eContrast
-
M101.2 Application
Sections M301 through M304 shall be applied to diagnostic equipment, based on the patient positions that the equipment supports, during patient transfer and diagnostic use....
-
5.2.1.1 Transfer Surface Width
The transfer surface should be 28 inches wide minimum for equipment used by patients in a supine, side-lying, or prone position....
-
M301.4 Lift Compatibility
An overhead lift (and possibly a gurney-based transfer) may be used in lieu of the provisions for clearances in or around the base of equipment to accommodate the legs of portable floor...
-
5.8 Wheelchair Spaces Recommendations for M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
5.8 Wheelchair Spaces Recommendations for M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair...