Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
Search Results "Sloped Sidewalk"
-
11B-1009.3.2 Submerged depth
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
1.1.10 Ramps
Measure accessible ramps for overall running slope and cross slope as well as local running slope and cross slope variations (flatness) in accordance with Sections 1.1.11, 1.1.12, 1.1.13...
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....
-
Wading Pools: ADA Standard Section 242.3
Section 242.3 covers scoping requirements in the current ADA Standards for wading pools.
-
C1-2. Accessible Route
Is an accessible route provided from public sidewalks and public transportation stops on the polling site (if provided) to the accessible entrance of the building?...
-
5b. Ramp Slope
Is the slope (up or down the ramp) no more than 1:12? [ADA Stds 4.7.2] Note: 1:12 is one inch of vertical height for 12 inches of horizontal distance. Yes _____ No _____...
-
11B-242.3 Wading pools
Accessible means of entry shall comply with sloped entries complying with Section 11B-1009.3....
-
11B-242.3 Wading pools
Accessible means of entry shall comply with sloped entries complying with Section 11B-1009.3....
-
4.2.8 Slope
The slope of the clear floor or ground space required by section 4.2.6 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
4.5.3 Slope
The slope of the clear floor or ground space for trash, recycling, and other essential containers shall not exceed 1:48 (2 percent) in any direction. Exception....
-
Accessible Sidewalks 1: Pedestrians who use Wheelchairs
Requires the Registered User plan or above. Login!
-
1.2.7
1.2.7 When local variations (flatness) for cross slope of ramps are measured according to 1.1.14 at least 80% (rounded to the nearest whole number) should not exceed a 2% slope....
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
DOT Memorandum: INFORMATION: Snow Removal on Sidewalks Constructed with Federal Funding
Department of Transportation Federal Highway Administration MEMORANDUM Subject: INFORMATION: Snow Removal on Sidewalks Constructed with Federal Funding Date: August 27, 2008 From...
-
B6. Curb Ramp Slope
If a curb ramp is provided, is the slope of the ramp surface (not counting the side flares) no more than 1:12? [ADA Stds 4.7.2] Yes _____ No _____...
-
3306.2 Walkways
A walkway shall be provided for pedestrian travel in front of every construction and demolition site unless the applicable governing authority authorizes the sidewalk to be fenced or closed...
-
3306.2 Walkways
A walkway shall be provided for pedestrian travel in front of every construction and demolition site unless the applicable governing authority authorizes the sidewalk to be fenced or closed...
-
Q5.) What dimensions and conditions can practitioners reasonably consider to be compliant when the conditions, as constructed, do not meet the technical requirements exactly and there are no official, published, industry-developed tolerances?
Sloped concrete and asphalt surfaces are an excellent example of this problem. ...
-
Handrails: ADA Standard Section 1009.3.3
At least two handrails complying with 505 shall be provided on the sloped entry....