Cross Slope The cross slopes of gangways, transition plates and floating piers that are part of an accessible route must be designed and constructed to not exceed a maximum of 2 percent...
Search Results "Shower Slope"
Commonly Searched Documents
-
Cross Slope
-
2c
Do all large showers have faucet controls that are easily operable with one hand without tight grasping, pinching, or twisting of the wrist (i.e.: levers, wrist blades, single arm, etc.)...
-
1.1.14 Flatness of ramp cross slope
1.1.14 Flatness of ramp cross slope....
-
4.6.5 Slope
The slope of the clear floor or ground space required by section 4.6.4 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
11B-608.6 Shower spray unit and water
11B-608.6 Shower spray unit and water....
-
Cross Slope and Surfaces [4.8.6]
The cross slope (2% maximum) must be minimized because it makes wheelchair travel difficult by distributing more weight and required force to one side and causing front casters to veer....
-
11B-608.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
11B-608.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
1f
Is there a horizontal grab bar on the wall alongside the shower seat (but not behind the shower seat) for stabilization and to aid in transfer from a wheelchair to the folding shower seat...
-
Outdoor Rinsing Showers [1011.2, 1011.3, and 1011.7]
The shower pedestal or wall with the shower heads must be at the rear end of the clear ground space. At least one hand-held shower spray unit must be provided....
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
1.2.5 Ramps
When overall running slope and cross slope for accessible ramps are measured according to Sections 1.1.11 a recommended tolerance for these slopes is +0.5%....
-
608.2 Size and Clearances for Shower Compartments
Shower compartments shall have sizes and clearances complying with 608.2....
-
608.2 Size and Clearances for Shower Compartments
Shower compartments shall have sizes and clearances complying with 608.2....
-
608.2.2 Standard Roll-In Type Shower Compartments
608.2.2 Standard Roll-In Type Shower Compartments....
-
11B-608.2 Size and clearances for shower compartments
11B-608.2 Size and clearances for shower compartments. Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
Alternate Roll-in Showers
Specifications are provided for alternate roll-in showers, including their size and the location of entries (608.2.3)....
-
Outdoor Rinsing Showers
If outdoor rinsing showers are provided in a recreation site, provide at least one hand-held shower spray unit with a hose 59 inches (1,500 millimeters) long minimum....
-
11B-608.2.1 Transfer type shower compartments
mm) wide minimum entry on the face of the shower compartment....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
1.1.12 Ramp cross slope
1.1.12 Ramp cross slope....