608 Shower Compartments...
Search Results "Shower Slope"
-
608 Shower Compartments
-
1016.7.2 Cross Slope
This section requires the cross slope of outdoor recreation access routes to not be steeper than 1:48....
-
1013.3 Slope
The slope of the surface of tent pads, tent platforms, and clear ground spaces shall not be steeper than 1:48 in any direction....
-
1013.3 Slope
The slope of the surface of tent pads, tent platforms, and clear ground spaces shall not be steeper than 1:48 in any direction....
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 (2 percent) in any direction....
-
Shower Stalls (ADAAG 4.21)
Shower Stalls (ADAAG 4.21) Although ADAAG permits both transfer and a roll-in showers, roll-in showers were found in institutional facilities....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
2b
Are all large showers free of curbs or lips at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303....
-
4.21.7 CURBS
If provided, curbs in shower stalls 36 in by 36 in (915 mm by 915 mm) shall be no higher than 1/2 in (13 mm)....
-
1i
Are all of the small showers free of curbs or lips greater than 1/2" high at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
-
4.21.7 Curbs
If provided, curbs in shower stalls 36 in by 36 in (915 mm by 915 mm) shall be no higher than 1/2 in (13 mm)....
-
Slopes and Resting Intervals for Outdoor Recreation Access Routes
Running slope is the lengthwise slope of an outdoor recreation access route, parallel to the direction of travel....
-
Controls [4.21.5]
Controls [4.21.5] Controls and shower units can be located on any wall but where a folding seat is provided they must be located to be within reach of a person on the seat....
-
Sloped Entries
Sloped Entries Sloped entries must comply with ADAAG accessible route provisions (36 inch minimum width, maximum 1:12 or 8.33% slope), except that the surface does not need to be slip...
-
Running Slope
Running Slope—The ascent or descent of a trail segment expressed as a percentage of its length....
-
4.21.4 GRAB BARS
Figure 37 Grab Bars at Shower Stalls...
-
4.21.2 SIZE AND CLEARANCES
Shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
1.1.13 Flatness of ramp running slope
1.1.13 Flatness of ramp running slope....
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....