Exception: Hazardous building ordinances and programs mitigating unreinforced masonry buildings. 2....
Search Results "Mitigating Measures"
Commonly Searched Documents
-
1.1.8.1 Findings and filings
-
11B-502.6 Identification
Signs shall be 60 inches (1524 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. [2010 ADA Standards] 502.6 Identification....
-
202.6.1
The path of travel requirements of 202.4 shall not apply to measures taken solely to comply with federal architectural barrier removal requirements. 2....
-
1.2.2
1.2.2 When flatness of running slope for an accessible surface other than a ramp is measured according to Section 1.1.5 no more than 20% (rounded to the nearest whole number) of the measurements...
-
11B-703.8.7 Character spacing
Spacing shall be measured between the two closest points of adjacent low resolution VMS characters within a message, excluding word spaces....
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
Height and Depth: ADA Standard Section 605.2
Section 605.2 covers the current ADA Standards for the height and depth of urinals.
-
11B-605.2 Height and depth
Urinals shall be 13½ inches (343 mm) deep minimum measured from the outer face of the urinal rim to the back of the fixture....
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
-
Rotational Penetrometer
All of the test courses were measured using the Rotational Penetrometer under wet and dry conditions....
-
1.1.8.1 Findings and filings
Exception: Hazardous building ordinances and programs mitigating unreinforced masonry buildings. 2....
-
1.1.8.1 Findings and filings.
Exception: Hazardous building ordinances and programs mitigating unreinforced masonry buildings. 2....
-
PRIORITIES
A public accommodation is urged to take measures to comply with the barrier removal requirements of this section in accordance with the following order of priorities....
-
Dome Spacing: ADA Standard Section 705.1.2
detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch (17 mm) minimum, measured...
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
The original site characteristics result in a difference in finished grade elevation exceeding 30 inches (762 mm) and 10 percent measured between an entrance and all vehicular or pedestrian...
-
3. Service Animals
infection than people; therefore, service animals should not be excluded from such areas, unless an individual patient’s situation or a particular animal poses greater risk that cannot be mitigated...
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing...
-
Sec.36.304(d)(2)
, a public accommodation may take other readily achievable measures to remove the barrier that do not fully comply with the specified requirements....
-
CONCLUSIONS
• The low energy costs for manual wheelchair users on surfaces that were objectively measured as firm and stable increase dramatically on the surfaces that were not measured as firm...
-
5.8.2.8 Knee and Toe Clearance Recommendations Summary
Clearance Recommendations Summary Ultimately, all of the knee and toe clearance recommendations in sections 5.8.2.1 – 5.8.2.7 are summarized below, in Figure 5.8.2.8, which shows the measurements...
-
Highway standards suggesting possible applications for pedestrian surfaces
ASTM E 950-98(2004) Standard test method for measuring the longitudinal profile of traveled surfaces with an accelerometer established inertial profiling reference...
-
§ 36.304(d)(3)
achievable, a public accommodation may take other readily achievable measures to remove the barrier that do not fully comply with the specified requirements....
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.2.2
Section 608.2.2 covers the current ADA Standards for the size of standard roll-in type shower compartments.
-
Alignment: ADA Standard Section 802.3.1
The shoulder alignment point of the wheelchair space shall be measured 36 inches (915 mm) from the front of the wheelchair space....