Doors shall comply with the following: Doors shall not be less than 6 feet 8 inches (2032 mm) in height. ...
Search Results "High Energy Door"
Commonly Searched Documents
-
1132A.3 Width and height of interior doors and secondary exterior doors
-
1132A.3 Width and height of interior doors and secondary exterior doors
1132A.3 Width and height of interior doors and secondary exterior doors. Doors shall comply with the following:...
-
404.2.4.3 Recessed Doors and Gates
404.2.4.3 Recessed Doors and Gates....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
Opening Force
Section 404.2.9 addresses the opening force of doors and gates....
-
404.2.4.3 Recessed Doors and Gates
, measured perpendicular to the face of the door or gate....
-
Drinking Fountains for Standing Persons: ADA Standard Section 602.7
Section 602.7 covers the current ADA Standards for drinking fountains for standing persons.
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground.
-
404.2.4.3 Recessed Doors and Gates
, measured perpendicular to the face of the door or gate....
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5. ...
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5....
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5....
-
404.2 Manual Doors, Doorways, and Manual Gates
404.2 Manual Doors, Doorways, and Manual Gates. Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
Shower and Sauna Doors in Transient Lodging Facilities
Shower and Sauna Doors in Transient Lodging Facilities....
-
Door Maneuvering Clearance
Table 404.2.4.1 specifies maneuvering clearances for manual swinging doors and gates....
-
224.1.2 Guest Room Doors and Doorways
224.1.2 Guest Room Doors and Doorways....
-
224.1.2 Guest Room Doors and Doorways
Advisory 224.1.2 Guest Room Doors and Doorways....
-
F224.1.2 Guest Room Doors and Doorways
Advisory F224.1.2 Guest Room Doors and Doorways....
-
Maneuvering Space at Doors
Several commenters requested that the final Guidelines incorporate minimum maneuvering clearances at doors, as provided by the ANSI Standard....
-
404.2.2 Double-Leaf Doors and Gates
At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4.
-
404.2.2 Double-Leaf Doors and Gates
At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4.
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.