(2) American National Standard: Accessible and Usable Buildings and Facilities, 1998 edition, (ICC/ANSI A117.1-1998), may be obtained from the International Code Council, 500 New Jersey...
Search Results "Assurances from Contractors"
-
§100.201a(b)(2) ICC/ANSI A117.1-1998
-
§100.201a(b)(3) CABO/ANSI A117.1-1992
(3) American National Standard: Accessible and Usable Buildings and Facilities, 1992 edition, (CABO/ANSI A117.1-1992), may be obtained from the International Code Council, 500 New Jersey...
-
Mechanical Access Parking Garages
However, such facilities must provide at least one accessible passenger loading zone at vehicle drop-off and pick-up areas so that people with disabilities can transfer from vehicles (§209.5...
-
Vertical Access
necessary (§206.2.3.1) (or as needed to provide an accessible path of travel to an altered primary function area if not disproportionate to the cost (§202.4)), unless the building is exempt from...
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for applications...
-
§ 37.203(d)
before its next trip will reduce the transportation service the entity is able to provide, the entity may keep the vehicle in service with an inoperable lift for no more than five days from...
-
SECTION 1011 STAIRWAYS
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for applications...
-
11B-812.9 Surface marking
The centerline of the text shall be a maximum of 6 inches (152 mm) from the centerline of the vehicle space and its lower corner at, or lower side aligned with, the end of the parking space...
-
11B-407.4.10.1 Location
The ends of the support rail shall be 6 inches (152 mm) maximum from adjacent walls....
-
§ 38.109 Between-car barriers
Where vehicles operate in a high-platform, level-boarding mode, and where between-car bellows are not provided, devices or systems shall be provided to prevent, deter or warn individuals from...
-
SECTION 1011 STAIRWAYS
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for applications...
-
11B-407.4.10.1 Location
The ends of the support rail shall be 6 inches (152 mm) maximum from adjacent walls....
-
11B-812.9 Surface marking
The centerline of the text shall be a maximum of 6 inches (152 mm) from the centerline of the vehicle space and its lower corner at, or lower side aligned with, the end of the vehicle space...
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for applications...
-
101.3 Intent
and general welfare through structural strength, means of egress facilities, stability, sanitation, adequate light and ventilation, energy conservation, and safety to life and property from...
-
502.7 Relationship to Accessible Routes
Wheel stops are an effective way to prevent vehicle overhangs from reducing the clear width of accessible routes....
-
802.3.1 Alignment
The shoulder alignment point of the wheelchair space shall be measured 36 inches (915 mm) from the front of the wheelchair space....
-
707.6.1 Input Controls
Where membrane keys are the only method of input, each shall be tactilely discernable from surrounding surfaces and adjacent keys....
-
206.5 Doors, Doorways, and Gates
and exits of business establishments conducting business with the general public that are existing, under construction, or under contract for construction which would prevent a person from...
-
202.6 Architectural Barrier Removal
Removal of architectural barriers, pursuant to 28 C.F.R. s. 36.304, from buildings, structures or facilities shall comply with this code’s requirements for alterations unless compliance...
-
605.2 Height and Depth
Urinals shall be 13½ inches (345 mm) deep minimum measured from the outer face of the urinal rim to the back of the fixture. Figure 605.2 Height and Depth of Urinals...
-
NSS Questions and Concerns