An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
Search Results "Maximum Extent Practicable"
Commonly Searched Documents
-
403.5.3 Passing Spaces
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
Accessible Routes
Accessible route requirements in ADAAG address width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level, doors, egress, and areas...
-
Location of Controls
The final rule has been revised to require that controls and operable parts be located 15 inches maximum from the centerline of the seat toward the shower opening....
-
1011.7 Outdoor Rinsing Showers
The hand-held shower spray unit shall have at least one fixed position located 15 inches minimum (380 mm) and 48 inches (1220 mm) maximum above the ground....
-
Cross Slope
Cross Slope The cross slopes of gangways, transition plates and floating piers that are part of an accessible route must be designed and constructed to not exceed a maximum of 2 percent...
-
Cashier counters
Provide a section of counter that is a minimum of 36" wide by a maximum of 36" high or an auxiliary accessible counter at the following locations: i....
-
5.8.3 Breast Platform Recommendations
The height of the breast platform shall be 30 inches high minimum and 42 inches high maximum above the floor when in use by a patient seated in a wheelchair...
-
R302.6 Cross Slope
Except as provided in R302.6.1 and R302.6.2, the cross slope of pedestrian access routes shall be 2 percent maximum. Advisory R302.6 Cross Slope....
-
§ 36.302(f)(9)(i)
(i) Individuals with disabilities and their companions shall be permitted to purchase the same maximum number of tickets for an event per sales transaction as other spectators seeking to...
-
§ 35.138(i)(1)
(1) Individuals with disabilities and their companions shall be permitted to purchase the same maximum number of tickets for an event per sales transaction as other spectators seeking to...
-
608.3.2 Standard Roll-In Type Shower Compartments
Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls. Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers...
-
11B-1008.4.3 Play tables
The tops of rims, curbs, or other obstructions shall be 31 inches (787 mm) high maximum....
-
11B-603.5 Accessories
All operable parts, including coin slots, shall be 40 inches (1016 mm) maximum above the finish floor....
-
1008.4.3 Play Tables
The tops of rims, curbs, or other obstructions shall be 31 inches (785 mm) high maximum....
-
407.12.2.2 Obstructed Side Reach (Section-by-Section Analysis)
proposes that, where the operable part is located more than 10 inches, but not more than 24 inches, behind the vertical reference plane, the height of the operable part must be 46 inches maximum...
-
Slope [4.3.7]
A maximum cross slope of 2% is recognized for drainage. Steep cross slopes make travel by wheelchairs, including many power chairs, difficult by causing front casters to veer....
-
1011.7 Outdoor Rinsing Showers
The hand-held shower spray unit shall have at least one fixed position located 15 inches minimum (380 mm) and 48 inches (1220 mm) maximum above the ground....
-
§1630.14(d)(3) Incentives offered for employee wellness programs
The use of incentives (financial or in-kind) in an employee wellness program, whether in the form of a reward or penalty, will not render the program involuntary if the maximum allowable...
-
11B-1008.4.3 Play tables
The tops of rims, curbs, or other obstructions shall be 31 inches (787 mm) high maximum....
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-1008.4.3 Play tables
The tops of rims, curbs, or other obstructions shall be 31 inches (787 mm) high maximum....
-
11B-303.5 Warning curbs
A warning curb is not required when a guard or handrail is provided with a guide rail centered 2 inches (51 mm) minimum and 4 inches (102 mm) maximum above the surface of the walk or sidewalk...