The Aspen battery powered ADA pool lift is designed for installation in the decks of in-ground and above-ground pools/spas....
Search Results "Ground Surface"
Commonly Searched Documents
- Spectrum Aquatics Portable Aspen Pool Lift
-
309.2 Clear Floor Space
A clear floor or ground space complying with 305 shall be provided....
-
B.6.iii. - Is undue burden the only grounds for acquiring EIT that does not meet the applicable technical provisions?
No. There are several exceptions to the requirements of Section 508 (see section G).
- BraunAbility UVL Wheelchair Lift for Cutaway Buses and Paratransit Vans
-
Abstract
The purpose of the longitudinal surface study was to evaluate a variety of trail surface materials, and their ability to meet proposed accessibility requirements of firmness and stability...
-
Manual vs. Power (RMS Values)
Power wheelchair The last section demonstrated that the vibration data for the engineered surfaces are much more consistent than the outside surfaces....
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
Width and Length: ADA Standard Section 1002.4.4.1
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
Seat Height: ADA Standard Section 1009.2.4
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
11B-246.7 Trails and paths
Buildings and other functional areas shall be served by paths or walks with firm and stable surfaces....
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
Vision Lights: ADA Standard Section 404.2.11
Section 404.2.11 covers the current ADA Standards for vision lights on manual doors and gates.
-
Grab Bars: ADA Standard Section 1009.5.7
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
- Magnuson Group VESUVIO Ash Trays
-
605.3 Clear Floor Space
A clear floor or ground space complying with 305 positioned for forward approach shall be provided....