The hand-held shower spray unit is required to have at least one fixed position located 15 inches minimum and 48 inches maximum above the ground....
Search Results "Ground Surface"
Commonly Searched Documents
-
1011.7 Outdoor Rinsing Showers
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
309.2 Clear Floor Space
A clear floor or ground space complying with 305 shall be provided....
-
B.6.iii. - Is undue burden the only grounds for acquiring EIT that does not meet the applicable technical provisions?
No. There are several exceptions to the requirements of Section 508 (see section G).
- Magnuson Group VESUVIO Ash Trays
-
Abstract
The purpose of the longitudinal surface study was to evaluate a variety of trail surface materials, and their ability to meet proposed accessibility requirements of firmness and stability...
-
Manual vs. Power (RMS Values)
Power wheelchair The last section demonstrated that the vibration data for the engineered surfaces are much more consistent than the outside surfaces....
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
- Spectrum Aquatics Aspen Pool Lift
-
Width and Length: ADA Standard Section 1002.4.4.1
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
Seat Height: ADA Standard Section 1009.2.4
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
11B-246.7 Trails and paths
Buildings and other functional areas shall be served by paths or walks with firm and stable surfaces....
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
Vision Lights: ADA Standard Section 404.2.11
Section 404.2.11 covers the current ADA Standards for vision lights on manual doors and gates.
-
Grab Bars: ADA Standard Section 1009.5.7
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...