As to the two remaining projects, one was under construction at the time of trial and the other was anticipated to conclude in 2014. RT 2227:7-21; DTX I32. 96....
Search Results "Door Timing"
Commonly Searched Documents
-
b) Library Program
-
Section 37.167 Other Service Requirements
This means that any time a vehicle is to stop where a passenger can get off and transfer to another bus or rail line (or to another form of transportation, such as commuter rail or ferry...
-
Which Circulation Paths Are Usable Circulation Paths?
Exits, other than main exterior exit doors that obviously and clearly are identifiable as exits, should be marked by approved signs that are readily visible from any direction of approach...
-
1. Typical Issues for Individuals Who Use Wheelchairs, Scooters, or Other Mobility Devices
An accessible route is at least 36 inches wide and may narrow briefly to 32 inches wide where the route passes through doors or next to furniture and building elements....
-
Emergency Egress
life safety codes specify the minimum distances between rows of fixed seating in consideration of the number of seats per row, exit aisle widths, and the arrangement and location of exit doors...
-
Part 1. Typical Issues for Voters Who Use Wheelchairs, Scooters, or Other Mobility Devices
An accessible route is at least 36 inches wide and may narrow briefly to 32 inches wide where the route passes through doors or next to furniture and building elements....
-
11B-403.5.1 Clear width
The clear width for accessible routes to accessible toilet compartments shall be 44 inches (1118 mm) except for door-opening widths and door swings....
-
11B-403.5.1 Clear width
The clear width for accessible routes to accessible toilet compartments shall be 44 inches (1118 mm) except for door-opening widths and door swings....
-
Section 36.305 Alternatives to Barrier Removal (Preamble, Section-by-Section Analysis)
Similarly, if it is not readily achievable to ramp a long flight of stairs leading to the front door of a restaurant or a pharmacy, the restaurant or the pharmacy must take alternative measures...
-
11B-226.4 Baby changing tables
area served by the subject toilet room in the future, permitted under a subsequent edition of CBC, the baby changing table in a noncompliant location will have to be relocated at that time...
-
CCDA Accessibility Checklist for Building Inspectors, 2015 Edition
inspections that the trained building code official/building inspector verify all elements will be able to meet the minimum accessibility requirements of the California Building Code at the time...
-
Selection of Playgrounds
geographic area surrounding the Indiana University-Bloomington campus, Indianapolis and Chicago, within driving distance of the Bloomington-based research team and easily accessed at any given time...
-
Section 36.305 Alternatives to Barrier Removal (Section-By-Section Analysis and Response to Comments)
Similarly, if it is not readily achievable to ramp a long flight of stairs leading to the front door of a restaurant or a pharmacy, the restaurant or the pharmacy must take alternative measures...
-
803.1 General
Partitions and doors should be designed to ensure people using accessible dressing and fitting rooms have privacy equivalent to that afforded other users of the facility....
-
Common Problems with Courtrooms
Common Problems with Courtrooms Ø Doors are too heavy to open. Ø No assistive listening systems are provided for people who are hard of hearing. ...
-
803.1 General
Partitions and doors should be designed to ensure people using accessible dressing and fitting rooms privacy equivalent to that afforded other users of the facility....
-
803.1 General
Partitions and doors should be designed to ensure people using accessible dressing and fitting rooms privacy equivalent to that afforded other users of the facility....
-
Accessible Routes
accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level, doors...
-
Accessible Routes
Accessible route requirements in ADAAG address width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level, doors, egress, and areas...
-
D. Entering the Emergency Shelter
An accessible entrance must provide at least one accessible door with maneuvering space, accessible hardware, and enough clear width to allow people who use crutches, a cane, walker, scooter...
-
9.3.1 General
Visual notification devices shall also be provided in units, sleeping rooms and suites to alert room occupants of incoming telephone calls and a door knock or bell....
-
4.10.13* Car Position Indicators
In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
-
4.10.13* CAR POSITION INDICATORS
In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....