In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
Search Results "Side-Opening Door"
Commonly Searched Documents
-
11B-608.5.1 Reserved
-
Vertical Clearance [§307.4]
Vertical Clearance [§307.4] Headroom clearance of at least 80” high is required along all circulation paths (except at doors and doorways where a 78” minimum clearance is permitted to...
-
1009.7.2 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
-
Additional benefits of water closet clearance standards
Wheelchair users, including veterans returning from our Nation’s wars with disabilities, are taught to transfer onto toilets from the side....
-
Additional benefits of water closet clearance standards
Wheelchair users, including veterans returning from our Nation's wars with disabilities, are taught to transfer onto toilets from the side....
-
1133B.2.5.2
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.2 Doors. 1133B.2.5.2 Hand-activated door opening hardware, handles, pulls, latches, locks and...
-
A. Signs
If signs are provided for the following spaces, are the signs mounted on the wall (not the door) to the latch side of the door and centered 60" above the floor so that they can be easily...
-
A. Accessible Voting Program
Portable ramps (including curb ramps) up to and including ramps six feet long, with side edge protection. Portable wedges or wedge ramps. Floor mats....
-
Tips for Communicating with Individuals with Mobility Impairments
Offer assistance if the individual appears to be having difficulty opening a door....
-
5.1 Tell the Doctor and the Staff
For example, you could say, “Did you know that the front door is very heavy and difficult to open?”...
- Landscape Forms Inc. Presidio Trash Receptacle
- Door King Inc. 6050 / 6100 Residential and Commercial Swing Gate Operator
-
Floor and Ground Surfaces
Specifications for floor and ground surfaces address surface characteristics, carpeting, openings, and changes in level. ...
-
A4.1.3(19)(a)
A4.1.3(19)(a) Readily removable or folding seating units may be installed in lieu of providing an open space for wheelchair users....
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
General [9.1.1]
Where room numbers are provided, they must be raised and Brailled and located on the wall at the latch-sides of doors for safety and uniformity....
-
FIGURE INDEX
FIGURE INDEX Figure 104 Graphic Convention for Figures Figure 302.2 Carpet Pile Height Figure 302.3 Elongated Openings in Floor or Ground Surfaces Figure 303.2 Vertical Change...
-
Policies and Procedures
A store that has a special accessible entrance that remains locked during business hours will need to change the policy and keep the door unlocked when the store is open....
-
How to Use this Checklist
Gather Tools Checklist Clipboard makes it easier to write on the checklist Tape measure Electronic or carpenter’s level - 24 inches Door pressure...
-
§ 38.111(a)(4)
(4) Bi-level lounge cars shall have doors on the lower level, on each side of the car from which passengers board, complying with §38.113, a restroom complying with §38.123, and at least...
-
1007.7.4 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
- Door King Inc. 1803 Telephone Entry System
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
The clear floor space must be positioned for a parallel approach to the side of the bed and must be on an accessible route....