Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
Search Results "Building Permit"
-
11B-809.5.4 Prohibited use
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
4.1.3(17)(d)
(d) Where a bank of telephones in the interior of a building consists of three or more public pay telephones, at least one public pay telephone in each such bank shall be equipped with a...
-
ADAPTABILITY
The ability of certain building spaces and elements, such as kitchen counters, sinks, and grab bars, to be added or altered so as to accommodate the needs of either disabled or nondisabled...
-
Architectural models
Architectural models The focus group members also visited the National Building Museum’s “Washington: Symbol and City” exhibition where they examined tactile architectural models of the...
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
- PEMKO 5" Heavy Duty Threshold No. 1715
- Kohler Steward® Hybrid High-Efficiency Urinal
- Stanley QDC 300 Series Grade 1 Standard Duty Door Closers
- Kawneer North America 350/500 Tuffline™ Entrances
- Protege Fixed Wheelchair Lift 5442F
- Virtuoso Portable Wheelchair Lift 5460P
-
§382.61(a)
on which passenger aisle seats have armrests are equipped with movable aisle armrests on at least one-half of the aisle seats in rows in which passengers with mobility impairments are permitted...
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
1135A.1 General
Where front-loading clothes washers are not provided, management shall provide assistive devices, on request of the occupant, to permit the use of top-loading clothes washers....
-
Accessible Practice Putting Greens, Practice Teeing Grounds, and Teeing Stations at Driving Ranges
Section 238.3 of the 2010 Standards requires that five percent (5%) but at least one of each of practice putting greens, practice teeing grounds, and teeing stations at driving ranges must permit...
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
211.2 Minimum Number
EXCEPTION: Where a single drinking fountain complies with 602.1 through 602.6 and 602.7, it shall be permitted to be substituted for two separate drinking fountains....
-
C. Contrast
(Note: reflective signs are permitted if they are in addition to non-reflective signs.)...
-
11B-206.7.9 Team or player seating
Platform lifts shall be permitted to provide accessible routes to team or player seating areas serving areas of sport activity. [2010 ADAS] Advisory 206.7.9 Team or Player Seating....
-
Changes in Level [4.5.2]
Vertical changes in level up to ¼ inch are permitted without treatment along accessible routes. Changes in level ¼ to ½ inch must be beveled with a slope no greater than 1:2....
-
4.5.3 Slope
When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
M302.2.1 Height
The transfer surface is permitted to be positioned outside of the specified height range when not needed to facilitate transfer....
-
M301.2.1 Height
The transfer surface is permitted to be positioned outside of the specified height range when not needed to facilitate transfer....