(d) The overhead clearance between the top of the lift door opening and the sill shall be the maximum practicable but not less than 65 inches (1651 mm)....
Search Results "High Energy Door"
Commonly Searched Documents
-
§ 38.153(d)
-
1009.9 Signage
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. 2....
-
2. Question: What is the minimum width needed for a level boarding railroad passenger station platform to meet the accessibility requirements of the Americans with Disabilities Act (ADA)?
A level boarding intercity or commuter railroad passenger station platform can have a gap between the passenger car door threshold and the edge of the platform that is at the maximum horizontal...
-
BACKGROUND
First Floor Office Space Replace entry door hardware to all occupied offices with hardware, mounted between 34- and 48-inches high, that is operable with one hand and does...
- LowVis Guide: Indoor Navigation for the Visually Impaired
-
Problem One (Ramps)
Problem One: There is a six inch high step on the accessible route that has a ramp that is only three feet long, making the ramp too steep and, therefore, inaccessible....
-
T207.4.2. Large vehicles
EXCEPTION: Where high-back seats are provided, handrails located overhead or on overhead luggage racks shall be permitted instead of stanchions or handholds....
-
11B-308.1.1 Electrical switches
receptacle outlets, appliances or cooling, heating and ventilating equipment, shall comply with Section 11B-308 except the low reach shall be measured to the bottom of the outlet box and the high...
-
4.15.3 SPOUT LOCATION
The spout shall provide a flow of water at least 4 in (100 mm) high so as to allow the insertion of a cup or glass under the flow of water....
-
Side Reach [§308.3]
Fuel Dispensers The operable parts of fuel dispensers located on existing curbs can be up to 54” high....
-
11B-707.7.2 Characters
Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I"....
-
11B-308.1.1 Electrical switches
receptacle outlets, appliances or cooling, heating and ventilating equipment, shall comply with Section 11B-308 except the low reach shall be measured to the bottom of the outlet box and the high...
-
11B-308.1.1 Electrical switches
receptacle outlets, appliances or cooling, heating and ventilating equipment, shall comply with Section 11B-308 except the low reach shall be measured to the bottom of the outlet box and the high...
-
Closing
And I’ll tell you, I think your interest level is as high as any that I’ve seen in the first meeting. So I think Stephanie is certainly excited....
-
If a more recent edition of ANSI/BHMA Standards for automated doors is issued should that be followed instead of those referenced?
The specific editions of the ANSI/BHMA Standards referenced by the Standards are to be followed (although the Access Board intends to update references to keep them current)....
-
Roberta Null, Ph.D., ASID. Training for Blind and Low Vision Persons: Color Contrast
Corner Teaching Kitchen (slide 8) [The] corner kitchen (slide 8) has the 30-inch-high countertops, and [has been] re-designed for wheelchair users....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The circle symbol shall contrast with the door, either light on a dark background or dark on a light background....
-
11B-304.2 Floor or ground surfaces
spaces, and in similar spaces where people using wheelchairs and other mobility devices must park their mobility aids such as in wheelchair spaces, or maneuver to use elements such as at doors...
-
What Kind Of Documentation Is Sufficient To Support A Request For Testing Accommodations?
Past Testing Accommodations on Similar Standardized Exams or High-Stakes Tests. ...
-
904.4.2 Forward Approach
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided....
-
904.4.2 Forward Approach
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided....
-
1008.2 Accessible Routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches high (2030 mm) minimum....
-
§ 38.95(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater than 1/4 inch high, shall have a clear width of 30 inches and...
-
§ 38.125(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater than 1/4 inch high, shall have a clear width of 30 inches and...