Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
Search Results "Floor Slope"
Commonly Searched Documents
-
11B-602.4 Spout height
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
11B-813.2.1 Adult changing table
Adult changing tables shall be fixed to the floor or a wall and shall comply with Section 11B-813.2.1....
-
Telescopes and Periscopes
Whenever a telescope or periscope is provided, ensure that a separate telescope or periscope is available for use from a standing position (60 inches above the floor or ground surface is...
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor. 2. Floor space....
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
1134A.7, Item 2
Where the water closet is not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for installation of floor-mounted, foldaway or similar...
-
211 Drinking Fountains
Design 2010 Standards for Accessible Design What’s New/Different 4.1.3(10)(a) Where only one drinking fountain is provided on a floor...
-
Drinking Fountains
Requirement: 4.1.3(10)* Drinking Fountains: (a) Where only one drinking fountain is provided on a floor there shall be a drinking fountain which is accessible to individuals who use...
-
1134A.7, Item 2
Where the water closet is not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for installation of floor-mounted, foldaway or similar...
-
11B-809.10.5.2 Reinforcement for grab bars
Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab bars. 2....
-
406.7 Islands
Each 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the curb ramp it...
-
Shooting Facilities
Fixed firing positions must have a 60-inch diameter space with slopes not steeper than 1:48 so a wheelchair user can turn around and have a level place from which to shoot....
-
Clear Deck Space
The slope of the clear deck space must not be greater than 1:48 (2%)....
-
Temporary Solutions for Election Day
Suggestion: Install a portable ramp no steeper than 1:12 slope with edge protection and handrails...
-
708.4 Residential Dwelling Unit Communication Systems
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with 708.4....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
708.4 Residential Dwelling Unit Communication Systems
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with 708.4....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
M17
Is the top of the toilet seat 17 to 19 inches above the floor? [ADA Standards § 4.16.3] Yes No...
-
4.24.2 Height
Sinks shall be mounted with the counter or rim no higher than 34 in (865 mm) above the finish floor....
-
9.5.2(2)(f)
(f) homeless shelters can comply with the provisions of (a)-(e) by providing the above elements on one accessible floor....